General Warnings; Programming - Beninca CP.RI624N Manual De Instrucciones

Ocultar thumbs Ver también para CP.RI624N:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 25
The CP.RI624N electronic control unit may be used for the control of 1 or 2 motors 24Vdc with power not higher than
120W+120W.
a) The electrical installation and the operating logic must comply with the regulations in force.
b) The leads fed with different voltages must be physically separate, or they must be suitably insulated with additional insulation of
at least 1 mm.
c) The leads must be secured with an additional fixture near the terminals.
d) Check all the connections again before switching on the power.
e) The unused N.C. inputs must be bridged.
Terminal No.
Function
1-2
Motor 1
3-4
Motor 2
5-6
Flashing light
7-8
Lock
9-10
SCA/2°Ch radio
11-12
24 Vac/dc
13
COM
14
SWO1
15
SWC1
16
SWO2
17
SWC2
18
PHOT
19
PHOT C
20
STOP
21
OPEN
22
CLOSE
23
PED
24
Step-by-Step
25
COM
26-27
BAR
30-31
Antenna
JF1-JF2
24VAC/dc
The programming of the various functions of the control unit is carried out using the LCD display on the control unit and setting
the desired values in the programming menus described below.
The parameters menu allows you to assign a numerical value to a function, in the same way as a regulating trimmer.
10
CP.RI624N control unit

GENERAL WARNINGS

INPUT/OUTPUT FUNCTIONS
CP.RI624N Control unit
Description
Connection, motor 1: 24VDC 120W max
Connection, motor 2: 24VDC 120W max
Connection, flashing light 24VDC 15W max.
Output, 12VAC/10W (5s) power supply for electric lock (7:0V, 8:+12V)
Normally open clean contact. Controlled by "2Ch" logic.
With 2ch logic Off: SCA contact, open gate indicator.
With 2ch logic On: Contact controlled by 2
Note: with "SRL" logic On, it performs the contact function of the courtesy light control, see
table of logic.
Output, accessory power supply, 24VAC/0.5A max.
IMPORTANT: If the battery charger board CB.24V is installed, the output (without mains
power connected) has a 24Vdc polarised voltage.
Make sure the devices are correctly connected (i.e. 11:+24Vdc / 12:-0Vdc).
Common for limit switches and all control inputs.
Input, OPEN limit switch, motor 1 (Normally closed contact)
Input, CLOSE limit switch, motor 1 (Normally closed contact)
Input, OPEN limit switch, motor 2 (Normally closed contact)
Input, CLOSE limit switch, motor 2 (Normally closed contact)
Input, photocell activated in both opening and closing phases
Input, photocell activated in closing phase only
Input, STOP push-button (Normally closed contact)
Input, OPEN push-button (Normally open contact).
Input, CLOSE push-button (Normally open contact)
Input, push-button for pedestrian use (Normally open contact), it controls the complete
opening of motor 1
Input, step-by-step push button (Normally open contact)
Common for all control inputs.
Input, sensitive edge contact
Resistive edge: "DAS" Jumper closed
Mechanical edge: "DAS" Jumper open
When the edge is activated, the gate movement is stopped and reversed for about 3s.
Connection to the insertable radio receiver card (30-signal/31-screen).
Input, 24VAC/24VDC power supply.
If buffer batteries are used, connect the CB.24V card (in option) as indicated in the table.

PROGRAMMING

radio channel of the receiver.
nd

Publicidad

Tabla de contenido
loading

Tabla de contenido