Beninca CP.J3 Manual De Instrucciones página 10

Ocultar thumbs Ver también para CP.J3:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 17
intervals.
- On the already memorised remote control, press the key corresponding to the function which must be
copied.
- Within 10 sec, press the key of the new transmitter to which the function should be assigned.
E.g.: on key 1 of TX "A" the P.P. function is stored; this function should be assigned to key 2 of the new
TX "B". Hence, press in sequence: hidden key of TX A >> key 1 of TX A >> key 2 of TX B
Cancelling all transmitters from the memory
- Keep the PGM key pressed for 15 sec, the DL1 LED and the courtesy light start flashing rapidly and
switch off at completion of cancellation.
- Release the PGM key and the memory is now erased.
N.B.:
For safety reasons, transmitters cannot be memorised during the open/close cycles of the motor.
When entering the memorise transmitter procedure, if the Power LED gives a prolonged blink and then
goes out, this signals that the receiver memory is full and no other transmitters can be memorised or that
the transmitter is not compatible.
After carrying out the electric connections of the control unit and the safety, control and indication devices,
the door opening and closing positions must be memorized.
First of all place the opening and closing mechanical stoppers in the correct position:
- manually release the door and completely close it. Place the closing mechanical stopper in the closed
position on the driving carrier and fix it.
- completely open the door. Place the opening mechanical stopper in the open position on the driving
carrier and fix it.
For further information, please refer to the Manual for use supplied with the operator.
Now the opening and closing positions can be stored in memory:
- with door stopped, press keys PGM+CL for about 5 seconds until the LED DL1 switches on
- the control unit is now ready to store the closing position in memory
- press the CL key and keep it pressed until the driving unit reaches the CLOSING mechanical stopper.
Then release the CL key and press PGM. The closed position is memorized by the control unit.
- Press the PP key and keep it pressed until the driving carrier reaches the OPENING mechanical stopper.
Release the PP key and press PGM. The open position is memorized by the control unit.
Note: it is possible to exit the memorization mode without any change by pressing PP+CL..
During the regular operation, after reaching the closure mechanical stopper, a short return control will be
given to cut off power from the belt.
In normal operating mode, the status of the control unit is displayed as follows:
- LED DL1 off: motor moving or motor stopped without alarm
- 3 flashes of LED DL1 with 1 sec interflash interval: photocell input engaged for more than 5 sec
- 4 flashes of LED DL1 with 1 sec interflash interval: amperometric sensor triggers.
- 5 flashes of DL1 LED, 1 sec interflash interval: encoder is malfunctioning.
N.B. In this case, the control unit switches to Service Man operating mode. The PP key controls the
movement of the door as long as it is kept pressed.
Note: After checking the device, cut off power and power again to reset the control unit.
- 6 flashes of the LED with 1 sec interflash interval : disconnected motor
- 7 flashes of LED DL1 with 1 sec interflash interval: P.P. input engaged for more than 5 sec.
When a power failure occurs, either in the completely open or in the completely closed positions, at reset of
power the control unit returns to normal operating mode. If a power failure occurs when the door is moving
open or closed, the door relay starts from the intermediate position. During opening, the door will stop
thanks to the activation of the amperometric sensor as soon as the driving carrier reaches the mechanical
stopper.
The normal operating mode of the system will be reset in the following operation.
10
Storage in memory of the opening and closing positions
Self-diagnosis of the control unit
Power failure

Publicidad

Tabla de contenido
loading

Tabla de contenido