Side Burner Conversion
1. Loosen the side burner screws to expose the side
burner valve.
Insert the tool onto the valve and unscrew orifice
from end of valve. Put the new orifice into the orifice
removal tool and tighten the new orifice into the
valve.
Make sure you are using the correct orifice, which is
marked "1.31". (Fig. 3)
2. Loosen the air shutter screw. Rotate the air shutter
to change the opening from the LP to the NG setting.
Tighten the screw to fix shutter in position. Engage
burner tube over valve as shown. (Fig. 4)
LP: Full open
NG: 1/4" open
All manuals and user guides at all-guides.com
56
Loosen
The side burner
Air shutter
Fig. 3
Fig. 4