Adjustment work before fixing the lift
- Check all bolts, nuts etc. are tight
- Check all connections and cylinders for leaks and tighten if necessary
- Observe the motor rotation direction. When the LIFT button is pressed, the
fan wheel on the motor must rotate in the specified direction.
The unit must start to pump oil after approx. 15 seconds.
If this is not the case, the direction of rotation must be changed.
For the following points, all the columns must be observed carefully during the entire process.
- Press the LIFT button. After a short time, the cylinder fills with oil and
tensions the lifting cables. Raise the lift until the crossbeams are approx. 50 mm above
the safety blocks or square timbers.
- Check the diagonals (see D1/D2 in the scale drawing with the technical data)
- The columns are then aligned with the crossbeams using a spirit level.
- A safety anchor is fitted to each column to secure it.
- The safety blocks or square timbers can then be removed.
- Move the lift to its lowest position with the LOWER button.
- Now check the position of the columns once again and fit the remaining
safety anchors, as described in the next step.
® Copyright ATH-Heinl GmbH & Co. KG, All rights reserved / Misprints and technical changes reserved / As of: 2020-03