Watson Marlow Pumps 620RA Serie Manual Del Usuario página 17

Tabla de contenido

Publicidad

Prevention and dissipation of electrostatic charge
All Watson- Marlow ATEX rated pumpheads include provision for the prevention and dissipation of
electrostatic charge. In order to dissipate electrostatic charge effectively there must be sufficient electrical
contact between the pumphead and the suitably earthed drive.
It is imperative that the 620 ATEX series pumpheads are earthed by connecting the earth terminal on the
track to earth.
Check the effectiveness of any earth connection by measuring its electrical resistance. The resistance must
not exceed 1 MΩ.