Teach-In With The Calibration Device - Balluff BTL7-A/E501-M Serie Manual De Instrucciones

Ocultar thumbs Ver también para BTL7-A/E501-M Serie:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 131
BTL7-A/E501-M _ _ _ _ -A/B/CD/Y/Z(8)-NEX-S32/KA _ _
Micropulse Transducer - Rod Style
8

Teach-in with the calibration device

NOTICE
Interference in function
Teach-in while the system is running may result in
malfunctions.
► Stop the system before performing teach-in.
Initial situation:
Transducer with magnet within measuring range
Activate teach-in
Œ
► Hold down
for at least 4 s.
Set null point
► Bring magnet to the new null point.
Œ
► Hold down
for at least 2 s.
⇒ The new null point is set once the button is released.
Set end point
► Bring magnet to the new end point.
► Hold down
for at least 2 s.
⇒ The new end point is set once the button is released.
Invert curves
► Simultaneously press
both LEDs are illuminated in red.
⇒ The curves of both outputs are inverted once the
buttons are released.
End teach-in
Œ
► Briefly press
and
⇒ The current position value is displayed once the
buttons are released.
Any of the individual steps for settings can be
selected. The teach-in process can be ended at
any time.
20
english
Œ
and
for at least 4 s, until
simultaneously (< 1 s).
LED legend:
LED display Displayed values (example)
LED1 LED2 At 0...10 V
1
> 4 s
1
> 2 s
2
> 2 s
1
2
> 4 s
1
2
< 1 s
LED not on
LED green
LED 1 and LED 2 flashing green-green in
LED red
alternation
Ignition protection
"nA" and "tb"
At 4...20 mA
5.39 V
9.15 mA
5.39 V
9.15 mA
1.04 V
4.82 mA
0.00 V
4.00 mA
9.89 V
19.13 mA
10.00 V
20.00 mA

Publicidad