CARE AND CLEANING (continued)
5. Attach grille (B) by pinching the mounting springs and inserting
them into the narrow rectangular slots in the fan housing (A).
Turn on power source. Test the unit
TROUBLESHOOTING
PROBLEM
The fan seems louder than it
should.
The fan is not clearing
humidity from the room.
Bluetooth device will not pair
with the fan.
Switch will not power up.
Switch has power, but the
fan does not.
Homewerks.com
POSSIBLE CAUSE
The CFM is too great for the space.
The damper is damaged or not working properly.
The bend in the duct is too close to the fan discharge.
The fan discharge is reduced to fit a smaller duct.
The fan body is not attached securely.
There is insufficient airflow intake in the room.
There is insufficient CFM.
NOTE: Using a tissue is not the correct method for
determining if the fan is operating properly. If the fan
clears steam from the room within approximately 15
minutes of completing your shower, then the fan is
operating properly.
Another device is already paired.
There is a wiring issue at the switch, or the power is
not turned on at the fuse box or circuit breaker.
The grille is not receiving a signal from the switch.
Neutral wire connection from the switch to the fan is
not engaging.
5
Housing slots
A
B
SOLUTION
Be sure the CFM rating on the fan matches the
square footage of your room.
Check the damper to ensure it is opening and closing
properly. If the damper has become damaged, please
call Customer Service.
Be sure you do not have any sharp bends in the duct
within 18 in. of the fan discharge.
Use the recommended size ducting to reduce fan
noise.
Be sure the fan is securely attached to the ceiling
joists.
Be sure a door or window is slightly ajar or open to
allow airflow. The fan is not able to draw air out of the
room without enough airflow.
Be sure the CFM rating of the fan matches the
square footage of your room.
Make sure BLUETOOTH
devices.
Check the wiring diagram on Page 5 and confirm
wiring is correct. Verify the power is turned on.
Turn off power. Verify the three connectors from the fan
housing (A) to the grille (B) are connected correctly, then
test. If necessary, disconnect the grille for 5 seconds,
then reconnect the grille and test. Repeat as necessary.
Turn off power. Confirm the house neutral wire is
connected to the switch neutral wire and fan neutral
wire. The switch included with this ventilation fan
requires a dedicated neutral wire connection. If a
neutral line is not present, one must be run by a
qualified electrician.
11
Mounting
springs
signal is turned off on other
®