11. Technical specifications
– Dimensions (H × W× D):
– Power supply:
– Output:
– Mounting height:
– Angle of coverage:
– Sensor reach:
– Twilight setting:
– Time setting:
– IP rating
– Ambient temperature:
– Protection class:
– Impact resistance
12. Troubleshooting
Unit without power.
– Fuse not switched ON or faulty.
• Switch ON fuse.
• Change faulty fuse.
– Break in wiring.
• Check wiring with voltage tester.
– Short circuit in mains power supply lead.
• Check connections.
– Any mains switch OFF
• Switch ON mains switch.
261 × 122 × 108 mm
220-240 V, 50/60 Hz
optimum mounting height: 2 m
L 30 S: 8 s - 35 min
– 26 –
max. 15 W / E27
L 30 S:180°
L 30 S: max. 10 m
L 30 S: 2-2,000 lux
-20 to +40°C
Index
IP44
II
IK07