RECEPTACLES
CAUTION
Receptacles may be marked with rating value greater
than generator output capacity.
• NEVER attempt to power a device requiring more amperage
than generator or receptacle can supply.
• DO NOT overload the generator. See "Don't Overload
Generator".
120 Volt AC, 20 Amp, Duplex
Receptacles
Each of these outlets (Figure 5) is protected against
overload by a push–to–reset circuit breaker.
Figure 5 — 120 Volt, 20 Amp Duplex Receptacle
Use each receptacle to operate 120 Volt AC, single–phase,
60 Hz electrical loads requiring up to 2,400 watts (2.4 kW)
at 20 Amps of current. Use cord sets that are rated for
125 Volt AC loads at 20 Amps (or greater).
5000W Portable Generator
120 Volt AC, 15 Amp Duplex
Receptacle
Each of these outlets is protected against overload by a
push–to–reset circuit breaker (Figure 6).
Figure 6 — 120 Volt AC, 15 Amp Duplex Receptacle
Use each outlet to operate 120 Volt, 60 Hz, single phase
loads requiring 1,800 (1.8 kW) watts at 15 Amps of
current.
10
OPERATION