BCM-W
The menu items may vary depending on the device configura-
tion. Not all menu items described below will necessarily ap-
ply to your device. Press the
the configuration. A 4-digit code will appear, e.g.
With the 4 digits tsav meaning:
t: Model
s: Number of switch-
ing outputs
a: Number of ana-
logue outputs
v: Device installation
type
H___i
Configuration
Equipment configuration
____
____
Display
Measurement display
Humidity
HuMi
Humidity main menu
Temperature
tEMP
Temperature main menu
b. E F
Basic EF
Basic Adv. Functions
DiA
Diagnostic
Diagnostics menu
Exit
E
Exit menu level
The individual menu items will not be shown if the option
does not apply. Example: With a=0 the menu items for config-
uring the analogue output does not apply. You can then skip
the description for this item.
The structure of the main menus Humidity (HuMi) and Tem-
perature (tEMP) is identical. Here you can configure the
switching outputs or the analogue outputs (if applicable).
The basic device settings can be changed. General settings can
be configured under Basic Settings Advanced Functions (b.EF).
These settings should be configured first, as they affect the
displays and settings for the individual menus. These settings
BX150101 ◦ 12/2021
key in display mode to open
h = humidity and tem-
perature measurement
2 or 4
0 of the 2
i = standard installation
(tank installation)
r = remote installation
Out 1
out1
Settings menu OUT1
out_
Out x
If applicable
Settings menu OUT1
Analog Out 1
An 1
If applicable
Settings menu Analog 1
E
Exit
Exit menu level
out_
Out X
If applicable
Settings menu OUTX
out_
Out X
If applicable
Settings menu OUTX
An 2
Analog Out 2
If applicable
Settings menu Analog 2
Exit
E
Exit menu level
are e.g. the units used and allocating switching outputs for li-
quid level and temperature measurement. The allocation of
the analogue outputs cannot be changed.
The Diagnostic (dia) menu further contains diagnostics op-
tions.
For the detailed illustration of the entire menu structure
please refer to the original operating instructions at the end
of this chapter.
5.2 BCM-WS
This explanation of the operation applies to the sensor ver-
sions without display.
5.2.1 Switching outputs
The sensor has one switching output assigned to humidity.
The threshold is preset to 80 %. The switching function is a NC
contact. This switching output can be configured ex works or
via the digital interface.
For the functionality please refer to chapter Switching out-
puts.
5.2.2 Analogue outputs
The sensor version features up to two 4-20 mA analogue out-
puts. The analogue outputs are available for the relative hu-
midity and temperature. The scale is preset and can be factory
configured or via the digital interface. By default the analogue
output shows the relative humidity as 0 % to 100 %. The ana-
logue output shows the temperature from -20 °C to 120 °C.
6 Maintenance
Always observe the applicable safety- and operating regula-
tions when performing any type of maintenance. Please refer
to the original operator's manual on the included CD or online
at www.buehler-technologies.com for maintenance informa-
tion.
7 Service and Repair
Please refer to the original operator's manual on the included
CD or online at www.buehler-technologies.com for a detailed
description of the unit including information on
troubleshooting and repair.