Air Motor Lubrication
To maintain the maximum performance of the air tool, it must be lubricated
each time it is used. Dust, dirt, rust and oil residue will build up inside the tool
and reduce the performance. An in-line oiler is recommended for proper auto-
matic tool lubrication (see Figure 1). If an in-line oiler is not available, the tool
can be lubricated manually through the inlet port (see Figure 3).
1.
Disconnect the air tool from the air supply.
2.
Turn the tool upside down and while depressing the trigger, add 4-6 drops
of Coleman Powermate® air tool oil #018-0059SP or SAE10 nondetergent
oil into the air inlet. NOTE: Depressing the trigger helps circulate oil in the
air motor.
3.
Reconnect the tool to the air supply, cover the exhaust port end with a
towel and run in forward and reverse directions for approximately 30 seconds to remove excess oil.
NOTE: If the tool remains sluggish after it has been lubricated, the internal components may need to
be cleaned.
To Clean:
Disconnect the air tool from the air supply and pour or spray a generous amount of WD-40® into the air inlet
with the trigger depressed. Connect the tool to the air supply, cover the exhaust port end with a towel and run in
forward and reverse directions for approximately 30 seconds. Follow the air motor lubrication instructions above
after cleaning is completed to re-lubricate the tool.
After oiling or cleaning, cover the exhaust port with a towel and operate the tool for a
few seconds to safely remove the excess oil. Clean the handle and surface of the tool
of any oil residue. Failure to cover the exhaust port and clean the tool, can
result in serious injury. Note: Keep the towel away from moving parts!
SYMPTOM
Tool will not run or runs
slowly
USER-MAINTENANCE INSTRUCTIONS
USER-MAINTENANCE INSTRUCTIONS

TROUBLESHOOTING GUIDE

TROUBLESHOOTING GUIDE
POSSIBLE CAUSE(S)
Grit in tool; tool gummed up
No oil in tool
Low air pressure
Air hose leaks
CORRECTIVE ACTION
Clean the air motor inside the tool with WD-40®
(see "user maintenance" section).
Add 4-6 drops of air tool oil into the air inlet of the
tool (see "user maintenance" section).
Adjust compressor regulator to 90 PSI.
Tighten and seal hose fittings with Teflon® tape if
leaks are found.