WEBTEC RFIK Serie Instrucciones De Funcionamiento página 6

Tester hidráulico reversible
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Normal Flow
Direction
Reverse
Flow
Direction
1. Remove safety disc cartridge with a 1 3/8" AF spanner.
2. Remove the internal disc holder in the cartridge with an 1 1/16" AF spanner.
3. Remove the two spent discs and fit new ORIGINAL WEBSTER discs, one on each side of
the spacer.
4. Tighten disc holder to 55 Nm (40 lb. ft.).
5. Check the seals.
6. Replace the entire cartridge assembly in the valve body.
4
Changing The Safety Burst Discs
N
S N
Pressure Control Valve
1
1) 1 3/8" AF
2) 1 1/16" AF
3)
4) 40 lb. ft. (55 Nm).
5)
6) 1 3/8" AF
2 Safety Discs
(Max. 420 bar / 6000 psi)
S
2;4
3
5
1;6
Normal Flow
Direction
Reverse
Flow
Direction
Spacer
Safety Disc
Cartridge

Publicidad