Zoeller 1450-0009 Manual Del Usuario página 5

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

HP
1/2
3/4
1
*NOTE: Wire length is the total distance from power source to pump depth.
PUMP MODEL
1450-0009
1451-0006
1452-0005
1452-0007
Submersible Cable and Ground Wire
Selection
WARNING: Turn off power at the electrical
service box before starting installation.
Finding the Depth of Your Well:
1. Tie a small, heavy weight to the end of a
cord (make sure the cord is at least 350 ft.
long). Lower this weight into the well until
it reaches the bottom. Take up any slack
and mark the string at ground level. Pull the
string from the well and measure from the
weight to your mark. This is the depth of your
well. Subtract 10 ft. from your well depth.
See Performance chart on page 2 to be sure
pump is rated for this depth. (FIG 1)
2. Drawdown is the lowest water level in the
well after the pump is turned on. If you know
the drawdown, the pump can be set 20 feet
below this level. However, the bottom of the
motor should be at least 10 feet from the top
of the well screen. (FIG 2)
CAUTION: If your pump depth is
200 ft. or more, you may want to consider
contacting a professional well pump
installer. Piping filled with water, along with
the weight of the pump, will be very heavy.
Be sure to have assistance during pump
installation.
MINIMUM WIRE SIZE CHART (GUAGE) - COPPER WIRE
VOLT
230
230
230
Control Box Chart
Maximum Cable Length In Feet Using AWG Cable*
#14
400
300
250
HP
CONTROL BOX MODEL
1/2
3/4
1
1
1
2
10 Ft. Min.
5
#12
650
480
400
1010-2336
1010-2337
1010-2338
1010-2338
Drawdown
Water Level
20 Ft.
Top of Well Screen
Bottom of Well
#10
1020
760
630