5. Installation, relocation and inspection
Electrical work
• Provide an exclusive circuit for power supply of the air conditioner.
• Be sure to observe the breaker capacity.
Warning:
• The customer should not install this unit. If the unit is installed incorrectly, fire, electric shock, injury due to a falling unit, water leakage, etc.
may result.
• Do not connect using branched outlet or an extension cord, and do not attach many loads to one electric outlet.
A fire or electric shock may result from poor contact, poor insulation, exceeding the permissible current, etc.
Consult your dealer.
Caution:
• Apply grounding
Do not connect a grounding wire to a gas pipe, water pipe, lightning rod or ground wire of a telephone.
If a grounding is incorrect, it may cause an electric shock.
• Install an earth leakage breaker depending on the place where the air conditioner is to be installed (humid place, etc.).
If the earth leakage breaker is not installed, it may cause an electric shock.
Inspection and maintenance
• When the air conditioner is used for several seasons, the capacity may be lowered due to dirt inside the unit.
• Depending upon the conditions of use, an odor may be generated or dirt, dust, etc. may prevent proper drainage.
• It is recommended to apply inspection and maintenance (charged) by a specialist in addition to normal maintenance. Consult your dealer.
Also consider operation sound
• Do not put an object around the air outlet of the outdoor unit. It may cause lowering of capacity or increase operating sound.
• If abnormal sound is heard during operation, consult your dealer.
Relocation
• When the air conditioner is to be removed or reinstalled because of rebuilding, moving, etc., special techniques and work are required.
Warning:
Repair or relocation should not be done by the customer.
If this is done incorrectly, it may cause a fire, electric shock, injury by dropping of the unit, water leakage, etc. Consult your dealer.
Disposal
• To dispose of this product, consult your dealer.
6. Specifications
Model
Function
Power supply
Capacity
Input
Indoor unit
Airflow (Lo-Me-Hi)
Noise level (Lo-Me-Hi)
Weight
Outdoor unit
Noise level
Refrigerant R410A
Weight
Notes: 1. Rating conditions (cooling) Indoor : 27°C DB, 19°C WB
2. Rating conditions (heating) Indoor : 20°C DB
3. Specifications subject to change without notice.
Guaranteed operating range
Upper limit
32°C DB, 23°C WB
Cooling
Lower limit
21°C DB, 15°C WB
Upper limit
Heating
Lower limit
Units should be installed by licensed electric contractor accordingly to local code requirement.
If you have any question, consult your dealer.
SLZ-KA25VA (L)
Cooling
Heating
2.5
kW
BTU/h
8,500
10,200
0.69
0.83
kW
SLZ-KA25VA (L)
8-9-10
CMM
dB
28-31-37
16.5 + Grille 3
kg
SUZ-KA25VA
46
dB
kg
0.90
33
kg
Outdoor : 35°C DB
Outdoor : 7°C DB, 6°C WB
Outdoor
Indoor
KA25, KA35
46°C DB, – 43°C DB, –
-10°C DB, –
27°C DB
24°C DB, 18°C WB
20°C DB
-10°C DB, -11°C WB
SLZ-KA35VA (L)
Cooling
Heating
~/N, 230V, 50Hz
3.0
3.5
4.0
11,900
13,600
1.06
1.10
SLZ-KA35VA (L)
8-9-11
29-33-38
16.5 + Grille 3
SUZ-KA35VA
48
1.05
35
KA50
SLZ-KA50VA (L)
Cooling
Heating
4.6
5.0
15,700
17,100
1.63
1.55
SLZ-KA50VA (L)
8-9-11
30-34-39
16.5 + Grille 3
SUZ-KA50VA
55
1.6
53
17