13 - PROGRAMMING THE CONTROL UNIT

-PrG
The configuration menu
items; the display shows the selected item.
i
By pressing
, you will pass to the next item; by pressing
will return to the previous item.
By pressing OK, you can view the current value of selected item
and possibly change it.
FinE
The last menu item (
) allows storing the carried out changes
and going back to the control unit normal operation.
You must exit from programming mode through this menu item if
you do not want to lose your configuration.
m
WARNING: in case no operation is carried out for more
than one minute, the control unit exits from the
programming mode without saving any of your setups and
changes, which will get lost.
i
h
By holding down the
or
keys, configuration menu items will
FinE
scroll fast, until item
is viewed.
In this way, you can quickly reach either the top or bottom of the
list.
PARAMETER
VALUE
dir
dX
SX
P.APP
0 - 1 00
t.PrE
0.5" - 1 '00
no
t.PCh
0.5" - 1 '00
no
vEL
3.5 - 26.0
vEL.r
3.5 - 26.0
rAM
0 - 6
consists in a list of configurable
h
, you
DESCRIPTION
Gate direction (the direction you see from the inside)
The gate opens rightwards
The gate opens leftwards
Partial opening
The percentage of the path the gate performs in the case of opening
using the Pedestrian Start command
Pre-blinking time
Before any gate movement, blinker will be activated for
warn about the incoming motion (adjustable time from 0.5" to 1'00)
Function deactivated
Different closing pre-flashing time
If this parameter has a value assigned to it, the control unit will activate
pre-flashing prior to closure for the length of time set in this menu
(adjustable time from 0.5" to 1'00)
The closing pre-flashing time corresponds to
Speed during normal operation
This menu allows you to adjust gate speed during normal operation.
The value shown is in cm/s
Speed during slowdown
This menu allows you to adjust gate speed during slowdown.
The value shown is in cm/s
NOTE: The maximum value which can be set is equal to the value set in
vEL
the menu
Starting ramp
In order not to stress too much the motor, when the motion starts the
power is gradually increased, until reached the set value or 100% if the
take-off is enabled.
Higher is the set value, longer the length of time of the ramp, that is the
time necessary to reach the value of nominal power.
-PrG
t.PrE
t.PrE
- 44 -
FinE
dir
P.APP
DEFAULT
MEMO
dX
25
1 .0"
time, to
no
18.0
6.0
4