In the following tables you can fi nd meaning of all diff erent position of dipswitch for programming CBHF2-D 24V 25A/30A battery chargers.
> Dip1 Dip2 Dip3 Dip4 for the selection of the CHARGING CURVE
DIP1
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
ON
OFF
> Dip5 Dip6 for the selection of the CURRENT I1
DIP5
ON
OFF
ON
OFF
> Dip7 and Dip8 for the selection of the battery voltage
DIP7
ON
OFF
ON
OFF
MANTA 34 RS
CBHF2-D 24V 25A/30A DIP SWITCH CONFIGURATION
DIP2
DIP3
ON
ON
OFF
OFF
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
ON
ON
OFF
OFF
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
DIP6
CURRENT
ON
15A
ON
20A
OFF
25A
OFF
30A
DIP8
VB
ON
12
ON
24
OFF
36
OFF
48
DIP4
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
ON
OFF
ON
OFF
ON
OFF
ON
OFF
OFF
OFF
OFF
OFF
57
CHARGING CURVE
0
1
(Curve for lead-acid "wet
traction batteries")
2
3
4
5
6
(Curve for sealed lead-acid and
GEL batteries from Trojan and
other manufacturers)
7
8
9
10
11
(Curve for GEL batteries from Sonnen-
schein, DETA and other manufacturers)
12
13
14
15