IMPORTANT SAFEGUARDS
When using electrical equipment, basic safety precautions should always be
followed including the following:
READ AND FOLLOW ALL SAFETY
INSTRUCTIONS
1.
DANGER- Risk of shock- Disconnect power before installation.
DANGER – Risque de choc – Couper l'alimentation avant l'installation.
2.
This luminaire must be installed in accordance with the NEC or your local
electrical code. If you are not familiar with these codes and requirements,
consult a qualified electrician.
Ce produit doit être installé conformément à NEC ou votre code électrique
local. Si vous n'êtes pas familier avec ces codes et ces exigences, veuillez
contacter un électricien qualifié.
3.
If NEMA photo control is installed refer to NEMA Receptacle section for
instructions.
4.
If mounting bolts are completely removed in the field they should be hand
threaded (prior to use of power tools) to ensure proper engagement of the
thread when re-installing. Failure to pre-start threads may result in cross-
threading or stripping of the bolts during reinstallation.
SAVE THESE INSTRUCTIONS FOR
FUTURE REFERENCE
TO INSTALL:
1
Cover Tabs
LUMINAIRE INSTALLATION
STEP 1:
DO NOT
remove splashguard from fixture. If
mounting fixture to 1.25 IP pipe (1.66 O.D.),
there is no need to modify the splashguard. If
mounting fixture onto 2.0 IP pipe (2.38 O.D.),
remove the knockout of the splashguard thru
the rear opening of the fixture while the fixture
.
is closed
STEP 2:
To open cover, press tabs in on both sides of the
cover and carefully let the cover swing down,
Figure 1
see
. Splashguard may dislodge from
fixture, but should be repositioned once ready
Figure 2.
to mount. See
1 of 2
2
Pole
Splash
Mounting
Guard
Bracket
Adjustment
Steps
Mounting Bracket
Bolts
STEP 3:
Slide fixture on to pole through opening on the
rear of housing and through splashguard. See
Figure 2.
STEP 4:
To level fixture, use bubble level located inside
housing. Adjust leveling of fixture from side
to side. To level from front to back, slide pole
to different step in upper housing. Each step
changes the angle in 2.5° degree increments.
Figure 2.
See
STEP 5:
Once desired position is achieved, tighten
mounting bolts to the appropriate torque
INSTALLATION INSTRUCTIONS
• Prior to installation, store luminaire in a dry location
protected from rain, dust, and outdoor environment. If
equipped with a photocell receptacle, do not store or
install luminaire outdoors without immediately installing
a suitable photocell, shorting cap, or other compatible
device. Do NOT leave receptacle open to environmental
elements. Luminaires with a top-mounted photocell
receptacle should not be installed in an up-light position
or at a tilt greater than 45 degrees from the down-light
position.
TORQUE VALUES
Pipe
Pipe Position
Size
+5.0 degrees tilt
+2.5 degrees tilt
1.66 in
0 degrees (no tilt)
O.D.
-2.5 degrees tilt
-5.0 degrees tilt
+5.0 degrees tilt
+2.5 degrees tilt
2.38 in
0 degrees (no tilt)
O.D.
-2.5 degrees tilt
-5.0 degrees tilt
values specified in TORQUE VALUES table on
the back of the sheet. See
socket wrench).
STEP 6:
IMPORTANT - DO NO
torque levels on the mount bolts. Exceeding
recommended torque value resulting in
excessive deformation of mounting bracket will
cause stripping of mount hardware which could
lead to an unsafe mounting condition.
STEP 7:
Reference Electrical Connections section
for completing electrical connections.
XSP Series
LED Street Light
Includes: XSPSM Luminaires
Bolt Torque
Bolt Torque
Required
Required
(in-lbs)
(N-m)
275
31
275
31
275
31
275
31
275
31
225
25
225
25
225
25
225
25
225
25
Figure 2
(use 9/16"
T exceed these
CI379X22R0