INSTALLATION
MOUNT PUMP
Recommended mounting is vertical with pump head pointed downward or
horizontal sitting on motor base.
Select a dry location (to avoid water intrusion and pump damage) above the
solution tank. Best recommended location is above the solution tank in a
vertical position with the pump head pointed downward.
To prevent pump damage in the event of a pump tube leak, never mount the
pump vertically with the pump head up.
To avoid chemical damage from fumes, DO NOT mount pump directly over an
open solution tank. Keep tank covered.
Avoid flooded suction or pump mounted lower than the solution container. Draw
solution from the top of the tank. Pump can run dry without damage. If pump is
installed with a flooded suction, a shut-off valve or other device must be provided
to stop flow to pump during service.
1. Use the mounting bracket as a template to drill pilot holes in mounting location.
2. Secure bracket with fasteners or wall anchors. Slide pump into bracket.
Provide 8" clearance to allow pump removal.
To prevent damage, verify with a volt meter that the receptacle voltage
corresponds with the pump voltage.
On the S3V and the S4V models, after installation and after the settings are
adjusted, be sure to tighten the screw on the cover of the control panel.
Wall Mounting Bracket
USA and Canada 800.683.2378, International 904.641.1666
continued
Pump Head
S Fixed & Variable Series
21