Fault diagnosis and troubleshooting

Fault diagnosis and troubleshooting of the individual inverter is described in the
Steca Solarix PI 550 / PI 1100 operating instructions.
Fault
Cause
LED on slave does not
• Slave defective
light up
LED on master does
• Master defective
not light up
The system does not
• Parallel switch
work, although the
master and slave(s)
are in working order
LEDs on inverters sig-
• Wiring fault
nal a malfunction
9

Legal guarantee

In accordance with German statutory regulations, there is a 2-year legal guaran-
tee on this product for the customer.
The seller will remove all manufacturing and material faults that occur in the
product during the guarantee period and affect the correct functioning of the
product. Natural wear and tear does not constitute a malfunction. No legal
guarantee can be offered if the fault can be attributed to third parties, unprofes-
sional installation or commissioning, incorrect or negligent handling, improper
transport, excessive loading, use of improper equipment, faulty construction
work, unsuitable construction location or improper operation or use. Legal guar-
antee claims shall only be accepted if notification of the fault is provided imme-
diately after it is discovered. Guarantee claims are to be directed to the seller.
The seller must be informed before guarantee claims are processed. For process-
ing a guarantee claim an exact fault description and the invoice / delivery note
must be provided.
The seller can choose to fulfil the legal guarantee either by repair or replace-
ment. If the product can neither be repaired nor replaced, or if this does not
occur within a suitable period in spite of the specification of an extension period
in writing by the customer, the reduction in value caused by the fault shall be
replaced, or, if this is not sufficient taking the interests of the end customer into
consideration, the contract is cancelled.
Any further claims against the seller based on this legal guarantee obligation, in
particular claims for damages due to lost profit, loss-of-use or indirect damages
are excluded, unless liability is obligatory by law.
725259 | Z04 | 2012-11-06
–20 °C ... +45 °C, continuous load
0% ... 95% rel. humidity
IP20, for use in dry environments
206 x 117 x 64 mm
0.8 kg
max. 4 inverters PI 550 / PI 1100,
(4 data inputs (RJ45) and
4 230 V / 115 V inputs)
2 outputs 230 V / 115 V
2 Tarom connections
Remedy
Disconnect and replace slave
X
Replace master,
X
e.g. rewire system with a
previous slave as master
Replace parallel switch box
X
box defective
Check the wiring
X
23