7.3.4 Changing Parameter Values in the Operator Level
The parameters at the operator level are found in the parameter list in Chapter 7.1.3.
–
Turn the main switch on.
–
Press the "P" key, the first parameter at the operator level "F-000 c2" is shown.
–
The parameter can be selected by pressing the "+" or "-" key.
–
Press the "E" key, the value of the selected parameter e.g. "F-000 c2 002" is
shown.
–
The parameter value "002" can be changed by pressing the "+" or "-" key.
–
Press the "E" key, the changed value is temporarily saved and the next parameter
is shown
or press the "P" key, the changed value is temporarily saved and the same
parameter is shown.
–
Press the "P" key, the change is saved and the programming level exited.
7.3.5 Reducing the Maximum Speed
In order to optimally set the maximum speed of the machine to the current individual
application, a reduction of the maximum speed is possible.
After each completed seam the current value of the maximum speed is shown in the
display. This value can now be changed directly with the "+" or "-" key. The setting
range lies between the parameter values F-111 (maximum value) and F-121 (minimum
value).
Note!
There are two settings for the maximum speed: The value of the parameter 111 and the
reduction of the maximum speed through the "+/-" keys. The lower value always has
priority! When the maximum speed has been reduced with the "+/-" keys, an increase of
the parameter value 111 only becomes effective after the reduction has been cancelled .
7.3.6 Quick Information and Quick Entry of Setting Values (HIT)
When the functions are turned on via the 1, 2, 3, 4 and 9 keys, the corresponding values
are shown in the display for approx. 3 seconds for the quick information of the user.
During this time the current value can be changed immediately via the "+" or "-" key.
ATTENTION !
The maximum speed (value of the parameter 111) should
be set no higher than is listed in the parameter sheet (in
the accessories pack) for each class and subclass.
GB
43