4-Wire Cable from Power Supply to 3-Wire Cable from Cooktop
IMPORTANT: Use the 4-wire cable from power supply where local codes do not
permit connecting the frame-ground conductor to the Neutral (N) junction box
wire.
A.
4-wire cable from power
supply
B.
L1 wires
Ground (G) or bare ground
C.
wire (from cooktop)
D.
3-wire cable from cooktop
E.
Junction box
F.
Neutral wire (from power
supply)
G.
UL listed wire connector
L2 wires
H.
I.
UL listed or CSA approved
conduit connector
NOTE
• Usually L1 is Black, L2 is Red, Ground (G) is Green or bare wire and Neutral (N) is
White wire.
• Do not connect the bare ground wire to the Neutral (N) wire in the junction box.
Radiant Install_NZ30K7570R_DG68-00825A-03_EN+MES+CFR.indb 9
1. Disconnect power.
2. Remove Junction box cover if present.
3. Connect the flexible cable condult from
the cooktop to the junction box using
a UL listed or CSA approved condult
connector.
4. Tighten screws on condult connector, if
present.
5. Connect the two L2 wires together using
the UL listed wire connectors.
6. Connect the two L1 wires together using
the UL listed wire connectors.
7. Connect the Ground (G) or bare ground
wire from the cooktop cable to the
Ground (G) or bare ground wire (in the
junction box) using a UL listed wire
connectors.
8. Put a UL listed wire connector on the
end of the Neutral wire.
9. Install junction box cover.
10. Reconnect power.
3-Wire Cable from Power Supply to 3-Wire Cable from Cooktop
IMPORTANT: where local codes permit, 3-wire cable can be use to supply power.
In those cases connect connect cooktop ground wire to the neutral wire from the
junction box.
1. Disconnect power.
2. Remove Junction box cover, if present.
3. Connect the flexible cable condult from
4. Tighten screws on condult connector, if
5. Connect the two L2 wires together using
A.
3-wire cable from power
6. Connect the two L1 wires together using
supply
B.
L1 wires
7. Connect the Ground (G) or bare ground
Ground (G) or bare ground
C.
wire (from cooktop)
D.
3-wire cable from cooktop
E.
Junction box
F.
Neutral wire (from power
8. Install junction box cover.
supply)
9. Reconnect power.
G.
UL listed wire connector
L2 wires
H.
I.
UL listed or CSA approved
conduit connector
the cooktop to the junction box using
a UL listed or CSA approved condult
connector.
present.
the UL listed wire connectors.
the UL listed wire connectors.
wire from the cooktop cable to the
Ground (G) or bare ground wire (in the
junction box) using a UL listed wire
connectors.
English 9
1/13/2017 3:58:56 PM