Safety Notes
The shower system may only be used for bathing, hygienic
and body cleansing purposes.
Children as well as adults with physical, mental and/or
sensoric impairments must not use this shower system without
proper supervision. Persons under the influence of alcohol or
drugs are prohibited from using this shower system.
Do not allow the streams of the shower touch sensitive body
parts (such as your eyes). An adequate distance must be kept
between the shower and you.
The hot and cold supplies must be of equal pressures.
Electrical connection
The electrical connection may only be carried out by an
electrician!
Preinstall electrcal power 230 V/N/PE/50 Hz (length: 0.3 m)
The system must be protected via a leakage current protective
device (RCD/ FI) with a measurement difference current of ≤
30 mA.
Assembly basic kit (see page 68)
Assembly Finish set (see page 73)
Important! The fitting must be installed, flushed and tested
after the valid norms.
Where the contractor mounts the product, he should ensure
that the entire area of the wall to which the mounting plate is
to be fitted, is flat (no projecting joints or tiles sticking out), that
the structure of the wall is suitable for the installation of the
product and has no weak points.
The enclosed screws and dowels are only suitable for
concrete. For another wall constructions the manufacturer's
indications of the dowel manufacturer have to be taken into
account.
The performance of the waste must be of sufficient size.
The shower may only be connected following (downstream
from) a shut-off valve of the sanitary fitting.
Maintenance Instructions
The non return valves must be checked regularly according
to DIN EN 1717 in accordance with national or regional
regulations (at least once a year).

English
Technical Data
Operating pressure in front of the shower fitting:
Recommended operating pressure:
(1 MPa = 10 bar = 147 PSI)
Hot water temperature:
Recommended hot water temp.:
safety lock:
Warning: Exceeding this temperature can cause burns!
Fittings (see page 60)
Dimensions (see page 60)
Installation tool (see page 60)

Installation example

Installation examples with measurements and pipe dimensions
can be found starting on page 62.
Operation (see page 76)
Spare parts (see page 76)
Service Replace illuminant (see page 77)
Cleaning (see page 78)
Electrician
The installation and testing work must be performed by a skilled
electrician in observance of VDE 0100 part 701 and IEC
60364-7-701.
Assembly see page 60
max. 1 MPa
0,3 – 0,5 MPa
max. 60 °C
42 °C
38 °C