Preparing the Base Tool for Right-Angle and Straight Swivel Head A t t a c h m e n t
Disconnect the air supply.
Remove any nose assembly items.
Remove Stem Collector Bottle Assembly (71213-05100) or 71210-20400.
Replace assembly with Safety Cap (71213-20102 or 71210-20101).
Unscrew Jaw Spreader Housing 41 and remove with 'O' Ring 12
Remove Locknut 40, 'O' Rings 15 and 19, and Seal Housing 52. Do not refit these items.
Screw Stop Nut (71213-20200) onto the front of Head Piston 36 as far as it will go by hand.
Refit Jaw Spreader Housing 41 and 'O' Ring 12, tighten onto Head Piston 36, finally tighten Stop Nut against Jaw Spreader Housing.
The tool is now ready to be fitted with a swivel head. Instructions page 16.