The intervention threshold of the anti-crashing device (Encoder) during
SEAR
braking is adjusted *.
99:maximum sensitivity - 0: minimum sensitivity
Activated only with SERL:ON Logic. The activation time of the service light
TLS
is adjusted.
The force of the motor brake is adjusted.
Ibra
0: disabled braking - 1:minimum braking - 99: maximum braking
* WARNING: An incorrect setting of these parameters may cause danger.
MENU
The automatic closure is enabled or disabled
TCA
On: enabled automatic closure
Off: disabled automatic closure
The multi-flat function is enabled or disabled.
On: enabled multi-flat function. The P.P. (Step-by-step) impulse or the impulse
IbL
of the transmitter have no effect in the opening phase.
Off: disabled multi-flat function.
The rapid closure is enabled or disabled
On: rapid closure is enabled. When the gate is open or moving, the photocell
SCL
activation causes the automatic closure of the gate after 3 s. It is activated only
with TCA:ON
Off: rapid closure is disabled.
The operating mode of "P.P. Push button" and of the transmitter are selected.
PP
On: Operation: OPEN > CLOSE > OPEN >
Off: Operation: OPEN > STOP > CLOSE > STOP >
Forewarning flashing light enabled or disabled.
On: enabled forewarning flashing light. The flashing light is activated 3 s before
PRE
the starting of the motor.
Off: disabled forewarning flashing light.
During the TCA time, the blinker is enabled or disabled.
LTCA
On: Activated blinker.
Off: De-activated blinker.
The OPEN input mode is selected
On: OPEN input with WATCH function. To be used for the connection of timed
CLOC
opening/closing. (CLOSED contact - open gate. OPEN contact - normal op-
eration).
Off: OPEN input with OPEN function.
The Operator function is enabled or disabled.
On: Operator function enabled.
htr
During operation, the OPEN/CLOSE push-buttons must be kept pressed.
Off: Automatic operation.
During the TCA phase, the PP and PED controls are enabled or disabled.
IBCA
On: PP and PED controls are disabled.
Off: PP and PED controls are enabled.
The Encoder is enabled or disabled.
ENC
On: enabled Encoder, braking activated.
Off: disabled Encoder, braking deactivated
The TRIAC test is enabled or disabled.
tri
On: Test on: if TRIAC is faulty the motor does not start.
Off: no test on TRIAC is performed.
The code programmable transmitters is enabled or disabled.
On: Radio receiver enabled only for rolling-code transmitters.
CVAR
Off: Receiver enabled for rolling-code and programmable code transmitters
(self-learning and Dip Switch).
FUNCTION
Please comply with regulations in force!
FUNCTION
MEMO
MIN-MAX-(Default)
0-99-(0%)
1-240-(60s)
0-99-(50%)
MEMO
DEFAULT
(ON)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(OFF)
(ON)
(OFF)
(OFF)