Grohe Blue HOME 31 498 Manual Del Usuario página 152

Ocultar thumbs Ver también para Blue HOME 31 498:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 59
Service
Fault
Water not flowing
E1 in the display, no filtered water,
®
Blue
handle flashes red
E3 in the display, no filtered water • No connection between fitting and
E5 in the display, no filtered water,
®
Blue
handle flashes red
E7 in the display, no filtered water,
®
Blue
handle flashes red
®
E8 in the display, Blue
flashes orange
E9 flashes alternately with HI
in the display
EC in the display, Blue® handle
flashes white
No carbon dioxide in positions
Medium and Sparkling
* If the faults E1 to E7 occur three times or more, please contact GROHE customer service.
Reset error message E9, automatically approx. 20 minutes
after cooling down to max. 32 ° C or by interrupting the power
supply approx. 30 seconds after cooling.
• Let cool down the cooler for least 10 -15 min
• Press and hold the  and  buttons simultaneously until SE
flashes in the display.
• Release the buttons
• Wait about 10 Sek
• The remaining filter capacity will be displayed and error message
E9 is reset
If EE flashes or the problem cannot be rectified, interrupt the power
supply to the cooler/carbonator. Note down the serial number of the
cooler/carbonator and consult a specialist installer or contact the
GROHE Service Hotline via email under TechnicalSupport-
HQ@grohe.com.
®
The GROHE Blue
Chilled cooler/carbonator may only be repaired
by GROHE Service.
21
Cause
• Filter not installed correctly
• Hoses kinked
• Water supply interrupted
• Safety shut-off of pump
cooler/carbonator
• Cable or connector faulty
• Fault function of cooler/carbonator
• Humidity detected inside the cooler - Disconnect mains supply,
• Filter capacity exceeded
handle
• cooler/carbonator overheated
• CO
cylinder nearly empty
2
• CO
cylinder empty
2
Remedy
- Insert filter straight
1
(1
/
- 2 turns)
2
- Check hoses for kinks
- Open fully shut-off valves
- Disconnect mains supply,
wait 30 seconds and reconnect
- Insert filter straight
1
(1
/
- 2 turns)
2
- Check hoses for kinks
- Open fully shut-off valves
- Connect plug-in connector
- Contact GROHE Service
- Disconnect mains supply,
wait 30 seconds and reconnect
wait 15 minutes and reconnect
•If condensation the cooler is ready for operation after
that
•If leakage occurs, the error message occurs again and
the GROHE Service must be contacted.
- Change filter cartridge immediately
®
- Close Blue
handle, ensure ventilation and reduce
ambient temperature to max. 32 °C
- Let cool down the cooler for least 10 -15 min
- Reset error message E9, see below
- Replace CO
cylinder
2
- Replace CO
cylinder
2
Environment and recycling
For reasons of hygiene, it is not possible to recycle used filter
cartridges.
Used filter cartridges can be disposed of hazard-free as residual
waste.
You can purchase a refill set for the attached CO
online shop at www.shop.grohe.com.
The cooler/carbonator is an electrical device, to which return and
take-back obligations apply in many countries. GROHE participates
in such take-back systems in all relevant countries.
This category of device does not belong in the domestic
waste, but must be disposed of separately in accordance
with the relevant local national regulations.
*
*
*
*
cylinders via our
2

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

31543dc0

Tabla de contenido