Use only original spare parts and accessories. The use of other
parts will result in voiding the warranty and the CE marking, and
could cause injury.
The filter head must be replaced after 5 years by the GROHE
service.
Technical data cooler/carbonator electrical data:
• Connection:
• Voltage supply:
• Max. power consumption:
• Type of protection:
• Relative air humidity:
• Refrigerant:
• Safety shut-off of pump:
• Operating pressure:
• Max. CO
inlet pressure:
2
• Max. refrigerant pressure:
• WLAN:
• Bluetooth:
• Temperature class:
Sanitary data:
• Cooler/carbonator cooled water capacity:
• Operating pressure:
• Flow rate at 0.3 MPa flow pressure:
• Ambient temperature:
• Temperature
– Cooler/carbonator water inlet:
– Cooled water temperature:
• Sound pressure level LpA (frestanding):
• Adjustable bypass, factory setting:
• Filter capacity Bypass Position 2
(Carbonate hardness 17 - 24 °KH):
• Water connection
– Cooler/carbonator:
Electrical test data:
• Software class:
• Contamination class:
• Rated surge voltage:
The test for electromagnetic compatibility (interference emission
test) was performed at the rated voltage and rated current.
Technical data fitting:
• Flow pressure:
• Operating pressure:
• Test pressure:
To comply with noise levels if static pressure exceeds 5 bar, a
pressure reducing valve must be fitted.
Avoid major pressure differences between hot and cold water
supply.
• Flow rate at 3 bar flow pressure:
• Temperature
– Hot water inlet:
– Recommended (energy saving):
Water connection:
Thermical disinfektion of the fitting is possible.
19
All manuals and user guides at all-guides.com
Wall socket with earth wire,
protected via a 10 A fuse
230 V AC / 50 Hz
180 W
IP 21
max. 75%
0.035 kg - R600a
approx. 4:30 min
min. 0,2 MPa - max. 1 MPa
0.48 MPa
3.0 MPa
2,4 GHz, IEEE 802.11 b/g/n/e/i
v4.2 BLE
max. 0.6 MPa
approx. 2 l/min
4 – 35 °C
max. 24 °C
approx. 5 – 10 °C
50 ± 4 dB
max. 600 litres
corresponds to max. 12 months
cold - blue
2,500 V
0.2 – 0.9 MPa
max. 1 MPa
1.6 MPa
approx. 9 l/min
max. 70 °C
60 °C
cold - right
hot - left
GROHE ONDUS app and connection to the internet
A GROHE Blue cooler connected to the internet via Wi-Fi can be
integrated and configured in the GROHE ONDUS app. This app
can be used to deliver messages in the form of push notifications.
A WLAN router with internet access
(2.4 GHz, IEEE 802.11b/g/n) is required.
Only WLAN channels 1 – 11 can be used.
Installation of the app:
Apple:
Android:
If the app or the device firmware requires updating, the smartphone
must be located in the immediate vicinity of the GROHE Blue
cooler. In this way, possible interruptions in function can be
controlled and rectified.
Operating conditions
Interference sources
The transmitter/receiver unit operates in the ISM frequency band
(2.4 GHz). Installation in proximity to devices with the same
frequency band (e.g. WLAN devices, HF components, etc.
[observe manufacturer documentation!]) should be avoided.
Obstructions/barriers
N
Wireless reception can be impaired and interrupted under
unfavourable surrounding conditions, in buildings/rooms with
reinforced concrete walls, steel and iron frames or in proximity to
1.4 l
obstacles (e.g. furniture) made of metal. Where necessary, a
WLAN repeater must be connected to the main router in order to
increase the range of the radio signal.
Installation and commissioning
GROHE recommends a depth of min. 510 mm for
the cabinet.
Flush pipes thoroughly before and after installation
2
(observe EN 806)!
Adjust bypass of filterhead according to local carbonate
hardness and connect filter cartridge.
The carbonate hardness can be tested by using the enclosed test
strip or the relevant water supplier can provide information on the
carbonate hardness.
The fitting has a system-related run-on time of approx. 1 s.
A
2
Note: Make sure that the water inlet hose does not come loose
by movement when installing the cooler.
When transporting or installing the cooler/carbonator,
cooling fluid may have run into the lines.
In order to ensure that the cooling fluid has run back, the
cooler/carbonator may only be installed following a pause
of 24 hours.
Fit CO2 cylinder:
Twist the cylinder until there is a noticeable resistance. To ensure
there are no leaks, after reaching the stop tighten the cylinder by
turning it a further 1/4 of a turn.
Control:
The buttons have the following functions:
Filter replacement reset
Filter size selection and carbontate hardness adjustment
CO
-Reset
2