Technical Data
Submersible sewage pump GS 750.1
Art. No
Rated voltage
Degree of protection
Max. delivered quantity
Max. head of delivery Hmax
Max. immersion
Max. suction
Max. Water temperature
Service connection
Cable length
Weight
Read and understand the operating
instructions before using the appliance. Familiarise
with the control elements and how to use the
appliance properly. Abide by all the safety measures
stated in the service manual. Act responsibly toward
third parties.
The operator is responsible for accidents or risks to
third parties.
In case of any doubts about connection and operati-
on refer please to our customer center
This appliance can be used by child-
ren aged from 8 years and above
and persons with reduced physical,
sensory or mental capabilities or
lack of experience and knowledge
if they have been given supervision
or instruction concerning use of the
appliance in a safe way and under-
stand the hazards involved.
Cleaning and user maintenance
shall not be made by children wit-
hout supervision.
Children should be supervised in order to ensure
that they do not play with the tool. Always keep
children and unauthorised persons out of reach of the
appliance.
Specified Conditions of Use
The pump is solely used for drainage and for pum-
ping into and out of containers in the house, garden,
farm and agriculture and only for water. Respecting
technical data and safety precautions.
94600
220 - 240 V
Do not use this product in any other way as stated
for normal use. Not observing general regulations
IP X8
in force and instructions from this manual does not
16.500 l/h
make the manufacturer liable for damages.
9 m
Do not use pump at outside temperatures over 40 °C
7 m
or under 0 °C
35 mm
35 °C
1 1/2" IG/AG + 1" AG
+ 32mm + 25mm
10 m
6,4 kg
Safety Warnings
Check the cable and/or socket for damages before
the appliance putting into operation.
Do not grab the feeder cable, plunge the pump, lift or
carry it while it is connected to the grid!
It is necessary to make sure the connecting socket
was not near water and humidity and the plug was
protected against humidity.
Check the voltage. Technical data given on the type
label must correspond with electric network voltage.
Only use splash proof extension cables approved for
outdoor purposes.
The pump is not suited for long-run operation
(e.g. as a circulation pump in ponds or streams).
When used in this manner, its service life is curtailed
correspondingly. In these cases, then, use a time
switch to secure sufficient idle periods between
cycles of operation.
Do not leave the pump unattended while in
operation in order to prevent subsequent
damages caused by eventual malfunctions. Make
sure to disconnect the device from the grid if you
do not plan on using it.
Do not use the pump for drinking water!
The pump must not be used to pump waste
water.
The pump must not be connected to the
existing water-supply network as a pressure-
boosting device.
Never use the pump as a pool circulation
pump.
WARNING! Electric shock! There is a risk of
an injury caused by electric shock!
ENGLISH
15