ENGLISH
Selecting the operating mode
set the dip-switch SW2 indicated in the figure:
Int.2=ON; Int.3=OFF; Int.4=OFF
set the dip-switch SW2 indicated in the figure:
Int.2=OFF; Int.3=OFF; Int.4=OFF
Setting the V1 and V2 values
The appliance leaves the factory with default nominal settings V1=VMIN, V2=VMAX
Values V1 and V2 can be adjusted as follows:
Set the dip-switch SW2 indicated in the figure:
Restore the power supply. The motor automatically runs at the
Use the trimmer (see figure) to set V1temp to the desired value,
between V1nom and the saved V2 – 100Rpm
Det Int.1=ON. This produces two effects:
the V1temp value is saved as a new V1;
the motor automatically runs at V2temp;
Use the trimmer (see figure) to set V2temp to the desired value,
between the saved V1 + 100Rpm and Vmax;
Set Int.1=OFF. This produces two effects:
the V2temp value is saved as a new V2;
the motor automatically runs at V1temp
Set Int.4=OFF to lock the V1 and V2 values
14
Two-speed mode:
cut off the power supply
Adjustable speed mode:
cut off the power supply
Cut off the power supply
Int.1=OFF; Int.4=ON
V1temp speed
Cut off the power supply
ON
OFF
1 2 3 4
ON