CONNECTION OF FUME EXHAUST VENT
Important
Make the connection in compliance with
the relevant legal requirements, using ap-
propriate and recommended materials.
Connecting to a fan extractor hood
A
TESTING OF THE APPLIANCE
Important
Before it is put into service, the system must
be tested to check the operating conditions
of every single component and identify any
IT
malfunctions. In this stage, it is important to
check that all health and safety requirements
GB
have been complied with in full.
To test the system, make the following checks.
DE
1 - Turn on the gas supply tap and check that the
connections are right.
2 - Check that the mains gas is the same as that
FR
used for commissioning of the appliance, and
carry out the conversion procedure if necessary
ES
(see page 17)
RECCOMANDATIONES FOR ADJUSTMENTS
Important
Before making any type of adjustment, acti-
vate all the safety devices provided and de-
cide whether staff at work and those in the
vicinity should be informed.
English
A
ADJUSTMENTS
1 - Position the appliance underneath the hood (A)
(see diagram).
Important
The gas supply tap must open automatical-
ly when the fan of the extraction system is
switched on.
A
3 - Check that the burner is switching on correctly
and its combustion.
4 - Check the gas pressure and flow-rate at
maximum settings and adjust if necessary (see
page 12).
5 - Check that the safety thermocouple is working
correctly.
6 - Check that there are no gas leaks.
7 - Check that the nameplates specify the correct
gas for the country of use.
After testing, if necessary instruct the user in all the
skills necessary for putting the appliance into oper-
ation in conditions of safety, in accordance with le-
gal requirements.
In particular, turn off the gas supply tap and
prevent access to all devices which might
cause unexpected health and safety haz-
ards if turned on.