MS-1e
4 - Inactive
These ports are inactive at this time.
5 - Inactive
This port is inactive at this time
Connection of external devices to inactive ports is not required or recommended.
6 - Device ID
The rotary ID switches give the unit a unique Device ID. The switches are in hexadecimal format. All units
of the same device type must have a unique Device ID to function properly within a Vocia Paging World.
The Factory Default Device ID is 01. A Device ID of 00 is invalid and cannot be used.
To assign a Device ID of hex 07, leave the MSB switch on 0 and turn the LSB switch to 7. Device ID
switches should be set using a 0.1 inch (2.5mm) to 0.12 inch (3.0mm) flat blade screwdriver. More
information on setting IDs and the hexadecimal numbering scheme can be found in the Vocia Help File.
Changes made to the Device ID while connected to the network require a power cycle in order to take effect.
5
NOTE
NOTE