ASSEMBLY INSTRUCTIONS SUPERTECHNE
These instructions are fundamental for correct use and operation of the luminaire.
After installation, they should therefore be kept safely for future use.
GENERAL NOTES
• Conformity: European standards EN 60598-1/2005, EN 60598-2-1, EN 60598-2-
2/A1 and EN 60598-2-22/A1 (for emergency luminaires), EC Directives LV 73/23,
EMC 89/336, 93/68/EEC.
• The SUPERTECHNE line consists of recessed luminaires for indoor use only or
installed in dry recesses, free of acids, oils and grease.
• The degree of protection of these luminaires varies as follows:
luminaires with safety glass and solid bezel IP43 (exposed part)
and IP20 (recessed part);
luminaires without safety glass or with safety glass and bezel with
AVS system IP23 (exposed part) and IP20 (recessed part);
• All luminaires in the SUPERTECHNE range are suitable for direct mounting on
normally inflammable surfaces
In particular, for recessed luminaires, ensure the sides of the luminaire are at
least 50 mm from the recess. The top of the luminaire may, on the other hand, be
in direct contact with normally inflammable material. They should under no
circumstances be covered with insulating material.
The remote control gear must be placed at the side a minimum distance of 300
mm away and at least 50 mm from the side of the recess; if the cable connecting
the control gear (type Y) is damaged, it should be replaced by Reggiani SpA, its
Fig.
a = 50 mm
d = 300 mm
S U P E R T E C H N E
S U P E R T E C H N E
.
Technical Service or by duly qualified personnel (fig.
• The number enclosed in the symbol
(metres) at which the object to be illuminated should be placed. This distance is
measured along the optical axis of the luminaire, from the lamp side to the
nearest object to be illuminated.
Light sensitive objects could become discoloured if exposed to the action of the
sun's rays or artificial light sources. In order to increase safety and exposure time,
use of low UV emission lamps ("UV-STOP lamps") is recommended.
Important: the efficiency of the UV filter depends on the level of illumination
(Lux), distance of the light source, duration of exposure and light sensitivity of the
individual objects. REGGIANI SPA ILLUMINAZIONE declines all liability for the
possible deterioration of exposed objects.
• In the event of damage or breakage of safety shield
absolutely be replaced before the luminaire is turned on, ordering them from
REGGIANI SPA ILLUMINAZIONE.
Important: luminaires may only be used if complete with the safety shield
provided.
• In the case of ultra-low voltage luminaires
high current, the attached indicative table should be consulted (table
proceeding with installation to evaluate the cable section required. Use high
temperature resistant cable
Important: compliance with standards is guaranteed only if the luminaire is
powered by a safety transformer, or equivalent, complying with current standards.
Ultra-low voltage luminaires marked with the symbol
10
10
).
i ndicates the minimum distance
,
these must
(QR-CB), characterized by very
to connect the lamp and ballast.
do not require earthing.
) before