Airplane VCR 1002 Manual De Instrucciones Y Mantenimiento página 60

Reactor para cremas; tanque fusor
Tabla de contenido

Publicidad

Fabrication Nº:
Equipment:
OPERATING INSTRUCTIONS AND MAINTENANCE MANUAL
PID CONTROLS
Allow the configuration of PID parameters for temperature control process.
TEMPERATURE PID CONTROL
Parameter
Description
Input
Actual temperature of vessel
Set Point
Desired temperatura of vessel
Control OUT
% actual opening of steam regulation valve
Proportional
Proportional parameter for PID regulation
Integral
Integral parameter for PID regulation
Derivation
Derivative parameter for PID regulation
EN Manual
Selects Manual or Automatic steam regulation valve
opening.
SP Manual
Allows to introduce % opening of steam regulaton
valve in case manual mode is selected
Status
Shows the status of PID control
Error
Show if there is any fault in PID control
Note 1: PID values are to be set when the reactor is started after being installed in its final location.
Ref. ProJect / Revision:
721021-07 / R01
721021-70-1 / 721021-70-3
VESSEL FOR CREAMS – Mod. VCR 1002 / MELT TANK – Mod. MET 0400
Client:
UNIPHARMA
Date:
11-2015
MDI VCR (v1.0)
Default value
---
---
---
Note 1
Note 1
Note 1
---
---
---
---