Manufacturer warrants, to the purchaser and subsequent owner during
the warranty period, every new product to be free from defects in material
and workmanship under normal use and service, when properly used and
maintained, for a period of three years from date of manufacture. Parts that fail
within the warranty period, that inspections determine to be defective in material
or workmanship, will be repaired, replaced or remanufactured at Manufacturer's
option, provided however, that by so doing we will not be obligated to replace
an entire assembly, the entire mechanism or the complete unit. No allowance
will be made for shipping charges, damages, labor or other charges that may
occur due to product failure, repair or replacement.
This warranty does not apply to and there shall be no warranty for any
material or product that has been disassembled without prior approval of
Manufacturer, subjected to misuse, misapplication, neglect, alteration, accident
or uncontrollable act of nature; that has not been installed, operated or
maintained in accordance with Manufacturer's installation instructions; that has
been exposed to outside substances including but not limited to the following:
sand, gravel, cement, mud, tar, hydrocarbons, hydrocarbon derivatives (oil,
gasoline, solvents, etc.), or other abrasive or corrosive substances, wash
towels, etc. in all pumping applications. The warranty set out in the paragraph
1. DO read all installation material with the unit.
2. DO inspect unit for any visible damage caused by shipping. Contact dealer
if unit appears to be damaged.
3. DO remove all debris from the basin. Be sure that the pump will have a
hard, level surface beneath it. DO NOT install on sand, gravel or dirt.
4. DO be sure that the area is large enough to allow proper clearance for the
level control switch(es) to operate properly.
5. DO Always Disconnect Pump From Power Source Before Handling.
DO always connect to a separately protected and properly grounded circuit.
DO NOT ever cut, splice, or damage power cord (Only splice in a watertight
junction box).
DO NOT carry or lift pump by its power cord.
DO NOT use an extension cord.
6. DO install a check valve and a union in the discharge line.
DO NOT use a discharge pipe smaller than the pump discharge.
ELECTRICAL PRECAUTIONS- Before servicing a pump, always shut off the main power breaker and then unplug the pump - making
sure you are wearing insulated protective sole shoes and not standing in water. Under flooded conditions, contact your local electric company or a
qualified licensed electrician for disconnecting electrical service prior to pump removal.
Submersible pumps contain oils which becomes pressurized and hot under operating conditions. Allow 2½ hours after disconnecting before
attempting service.
CONDITION
A. Pump will not start or run.
B. Motor overheats and trips overload
or blows fuse.
C. Pump starts and stops too often.
D. Pump will not shut off.
E. Pump operates but delivers little or
no water.
F.
Drop in head and/or capacity after
a period of use.
If the above checklist does not reveal the problem, consult the Product Support Department. Do not attempt to service or otherwise
disassemble pump. Service must be peformed by a Zoeller Authorized Service Station. Go to www.zoellerpumps.com/servicestations to find
the Authorized Service Station in your area.
LIMITED WARRANTY
DO'S & DON'T'S FOR INSTALLING UNIT
SERVICE CHECKLIST
COMMON CAUSES
Check fuse, low voltage, overload open, open or incorrect wiring, open switch, impeller or seal bound mechanically,
defective capacitor or relay when used, motor or wiring shorted. Float assembly held down. Switch defective,
damaged, or out of adjustment.
Incorrect voltage, negative head (discharge open lower than normal) impeller or seal bound mechanically, defec-
tive capacitor or relay, motor shorted.
Float tight on rod, check valve stuck or none installed in long distance line, overload open, level switch(s) defec-
tive, sump pit too small.
Debris under float assembly, float or float rod bound by pit sides or other, switch defective, damaged or out of adjustment.
Check strainer housing, discharge pipe, or if check valve is used vent hole must be clear. Discharge head
exceeds pump capacity. Low or incorrect voltage. Incorrect motor rotation. Capacitor defective. Incoming water
containing air or causing air to enter pumping chamber.
Increased pipe friction, clogged line or check valve. Abrasive material and adverse chemicals could possibly
deteriorate impeller and pump housing. Check line.
© Copyright 2015 Zoeller
above is in lieu of all other warranties expressed or implied; and we do not
authorize any representative or other person to assume for us any other
liability in connection with our products.
Contact Manufacturer at, 3649 Cane Run Road, Louisville, Kentucky 40211
USA, Attention: Customer Support Department to obtain any needed repair
or replacement of part(s) or additional information pertaining to our warranty.
MANUFACTURER EXPRESSLY DISCLAIMS LIABILITY FOR SPECIAL,
CONSEQUENTIAL OR INCIDENTAL DAMAGES OR BREACH OF
EXPRESSED OR IMPLIED WARRANTY; AND ANY IMPLIED WARRANTY
OF FITNESS FOR A PARTICULAR PURPOSE AND OF MERCHANTABILITY
SHALL BE LIMITED TO THE DURATION OF THE EXPRESSED WARRANTY.
Some states do not allow limitations on the duration of an implied warranty,
so the above limitation may not apply to you. Some states do not allow the
exclusion or limitation of incidental or consequential damages, so the above
limitation or exclusion may not apply to you.
This warranty gives you specific legal rights and you may also have other
rights which vary from state to state.
7. DO NOT utilize this unit for pumping gasoline or other hazardous liquids.
8. DO test pump immediately after installation to be sure the system is
working properly.
9. DO review all applicable governing codes and verify that the installation
conforms to each of them.
10. DO consult manufacturer for clarifications or questions.
11. DO consider a two-pump system with an alarm where an installation may become
overloaded or primary pump failure would result in property damages.
12. DO consider a D.C. Backup System where a sump or dewatering pump is
necessary for the prevention of property damages from flooding due to A.C.
power disruptions, mechanical or electrical problems or system overloading.
13. DO inspect and test system for proper operations at least every 3 months.