40
Measurements
Permits selection of the type of measurement to be
shown on the display 4.
0 Real current
1 Real voltage
2 No measurement
Default 0
42
Adjustment step
Permits adjustment of the variation step on the up-
down keys.
Minimum Off, Maximum MAX, Default 1.
43
External parameter 1
Allows the management of external parameter 1 (mini-
mum value).
44
External parameter 1
Allows the management of external parameter 1 (maxi-
mum value).
3.4 Alarm codes
01/02/03
Temperature alarm
It is advisable not to switch off the equipment while
the alarm is on; the internal fan will thus keep oper-
ating and will help to cool the overheated parts.
10
Power module alarm
11
System configuration alarm
20
Communication alarm
21
Data loss alarm
3.5 Rear panel
1
Power supply cable
Connects the system to the mains.
2
Signal cable (CAN-BUS) input (RC)
3
Off/On switch
Turns on the electric power to the welder.
It has two positions, "O" off, and "I" on.
3.6 Sockets panel
1
Negative power socket
For connection of earth cable in electrode welding or of
torch in TIG.
2
Positive power socket
For connection of electrode torch in MMA or earth
cable in TIG.
4 ACCESSORIES
4.1 General
Operation of the remote control is activated when connected
to the power sources. This connection can be made also with
the system power on.
With the RC control connected, the power source control panel
stays enabled to perform any modification. The modifications
on the power source control panel are also shown on the RC
control and vice versa.
4.2 RC 100 remote control
The RC 100 is a remote control unit designed to manage the
display and the adjustment of the welding current and voltage.
"Consult the instruction manual".
4.3 RC 180 remote control
This remote control unit makes it possible to change the output
current without interrupting the welding process.
"Consult the instruction manual".
25