sangiorgio EES510 Manual De Operación Y Mantenimiento página 124

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

To stop the flow:
Tighten the drain filter.
When no more water comes out:
Unscrew the entire filter.
Clean the filter.
Verify that the drain propeller rotates easily.
Remove any debris and clean the inside if there
should be any.
Replace the drain pump filter and screw it firmly.
!
Warning! If the filter is not reinsert-
ed or screwed tightly, the water could spill
from the machine.
28
DEtErgEnt DraWEr clEaning
Having removed the detergent drawer, take
away the vent steam plate as shown in photo
below.
If it is clogged by foreign bodies or detergent, it
is advisable to break it small fragments taking
care not to push the lumps to the bottom to
prevent clogging of the internal circuit. Note
that the detergent is removed easily if treated
with hot water.

Publicidad

Tabla de contenido
loading

Tabla de contenido