Spray charts

Compressor Pressure Gauge
18 PSI or
less is HVLP
zone for
continuous
spray
Spraying Pressure Air Consumption
Pressure
Air CFM
Inside Cap
6 PSI
6.5
8 PSI
7.5
10 PSI
7.8
8
12 PSI
14 PSI
8.5
*The pressure at the compressor air outlet
when spraying gun.
10
8
6
4
2
0
6 PSI
8 PSI
Pressure inside air cap (PSI)
© Titan Tool Inc. All rights reserved.
All manuals and user guides at all-guides.com
Above 18 PSI is
conventional spray zone
for intermittent use only
PSI
Compressor Pressure*
9
15
18
20
(for intermittent use)
24
(for intermittent use)
10 PSI
12 PSI
14 PSI

cleanup

1. Turn off the compressor.
2. Remove the pressure pot hose from the pressure pot.
3. Relieve the pressure from the pressure pot and remove
the pressure pot cover.
4. Remove excess material from the pot (or remove the pot
liner), wiping down the inside of the pot and fluid pick-up
tube.
5. Place a container of the appropriate cleaning solvent into
the pressure pot to clean out the hose and gun.
6. Replace the cover, making sure the pickup tube is inside
the solvent container, and tighten the pot cover.
7. Connect the pressure pot hose, turn on the compressor
and adjust the pressure to 10 psi.
8. Depress the spray gun trigger while pointing the gun into
the material container. This will drain the material into the
container until all material has been pushed through.
9. Continue running the solvent through the hose and gun
until they are completely clean.

maintenance

maintaining the air Filter

The air filter on the compressor must be checked daily for paint
build-up on the filter pads. A clean filter pad is necessary to
prevent damage to the compressor and to maintain maximum
spraying performance.
Never clean the air filter with a flammable liquid or
solvent. Explosive vapors may accumulate in the
air tank and cause an explosion, resulting in
serious injury or death.
NOTE: A replacement filter pad is included with this
unit. Additional filter pads (P/N 600-467) can
be ordered through an authorized Titan service
center.
Regulator with optional moisture separator (P/N
0295742)
A moisture separator is available for separate purchase. A
moisture separator at the compressor air outlet reduces the
amount of water entering the spray gun. Check the moisture
separator sight glass periodically during operation and drain
water as needed.
NOTE: This unit has no other service parts and all
service must be performed by an authorized
service center.
Storage
To reduce the risk of electrical shock, do not
expose to rain. Store indoors.