It sets selection of the operating mode of the P.P. contact
On: With S.S. contact closed, the barrier opens and remains open, as soon as the S.S. contact
OPCL
reopens, the barrier immediately closes again.
Off: Normal operation of the S.S. contact
It enables or disables the photocells check on the PHOTO input, enabled both in closure and in
opening.
TST1
On: Check enabled. If the check has a negative outcome, no manoeuvre is commanded. See Fig.15
- "PHOTO TEST".
Off: Check the photocells on each disabled manoeuvre.
It enables or disables the "Forced opening function without mains) function (can only be enabled
with the emergency batteries connected and working).
On: Function enabled. In the event of no power supply, the barrier continues to work until the
aopf
voltage value of the batteries goes under 23V. Having reached this value, the control unit forces
an opening manoeuvre and remains open until the mains voltage is reset.
Off: Function not enabled.
It enables or disables reception of the transmitters duplicated by the "AK" series.
cvar
On: AK transmitters reception enabled
Off: AK transmitters reception disabled.
It enables or disables remote learning of the radio transmitters, as indicated in the "Transmitters
remote learning" paragraph.
rem
On: Remote learning enabled.
Off: Remote learning disabled.
MENU
By selecting this function, the receiver goes in waiting (Push) for a transmitter code to assign to the step-step function.
Press the key of the transmitter to assign to this function.
PP
If the code is valid, it is memorised and the message OK is displayed
If the code is not valid, the message Err is displayed
By selecting this function, the receiver goes into waiting (Push) for a transmitter code to assign to the second radio channel.
Press the key of the transmitter to assign to this function.
2Ch
If the code is valid, it is memorised ad the OK message is displayed
If the code is not valid, the message Err is displayed.
ntx
By selecting this function the LCD screen shows the number of transmitters memorized into the receiver.
By selecting this function, the receiver goes into waiting (Push) for a transmitter code to erase from the memory.
CLR
If the code is valid, it is erased and the message OK is displayed
If the code is not valid or not present in memory, the message Err is displayed
Completely erases memory of the receiver. Confirmation of the operation is requested.
RTR
By selecting this function the receiver goes into waiting (Push) for a new PGM pressure to confirm the operation.
At end of erasing the OK message is displayed
Displays the number of complete cycles (open+close) carried out by the automation.
When the <PG> button is pressed for the first time, it displays the first 4 figures, the second time it shows the last 4. Example <PG> 0012 >>> <PG>
3456: made 123.456 cycles.
This function enables to activate the maintenance request notice after a number of manoeuvres determined by the installer.
To activate and select the number of manoeuvres, proceed as follows:
Press button <PG>, the display will show OFF, which indicated that the function is disabled (default value).
With the buttons <+> and <-> select one of the numeric values proposed (from OFF to 100). The values are intended as hundreds of cycles of ma-
noeuvres (for example: the value 50 indicates 5000 manoeuvres).
Press the OK button to activate the function. The display will show the message PROG.
The maintenance request is indicated to the user by keeping the indicator lamp lit up for other 10 sec after the conclusion of the opening or closing operation.
RESET of the control unit. ATTENTION!: Returns the control unit to the default values.
Pressing the <PG> button for the first time causes blinking of the letters RES, pressing the <PG> button again resets the control unit. Note: The trans-
mitters are not erased from the receiver nor is the access password.
All the logics and all the parameters are brought back to default values, it is therefore necessary to repeat the autoset procedure.
14.3.4) RADIO (RADI)
14.3.5) CYCLES NUMBER (NMAN)
14.3.6) MAINTENANCE CYCLES (MACI)
14.3.7) RESET (RES)
FUNZIONE
(OFF)
(OFF)
EN
(OFF)
(ON)
(OFF)