PSA-RP71GA
PSA-RP100GA
S
Y
M
B
O
L
N
A
M
E
P.B
INDOOR POWER BOARD
I.B
INDOOR CONTROLLER BOARD
FUSE
FUSE (T6.3AL250V)
ZNR
VARISTOR
CN2L CONNECTOR (LOSSNAY)
CN32 CONNECTOR (REMOTE SWITCH)
CN41 CONNECTOR (HA TERMINAL-A)
CN51 CONNECTOR (CENTRALLY CONTROL)
LED1
POWER SUPPLY (I.B)
LED2
POWER SUPPLY (R.B)
LED3
TRANSMISSION (INDOOR-OUTDOOR)
INDOOR UNIT
P.B
ORN
MF
ML
C
RED
I.B
LOUVER
FAN
POWER
1 3 5 7
1 3
1 3
(WHT)
CNL
CNDK
(YLW)
(RED)
X2
X6
X5
X4
X2
X6 X5 X4
LED3 LED2 LED1
SW2
SW1
SWE
ON
OFF
TH2
Refer to tables 1
and 2 for service PCB.
TH1
PSH -P.GAH
TH5
models only
HEATER
2
CN24
1
(YLW)
I.B
26H
RED
6
YLW
1
6
RED
88H
5
YLW
YLW
Table 1
SW2
MODELS
Service board
1 2 3 4 5
PSA-RP.GA
ON
PSH-P.GAH
OFF
Table 2
SW2
MODELS
Service board
1 2 3 4 5
PSA-RP71GA
ON
PSH-P71GAH
OFF
1 2 3 4 5
PSA-RP100GA
ON
PSH-P100GAH
OFF
1 2 3 4 5
PSA-RP125GA
ON
PSH-P125GAH
OFF
1 2 3 4 5
PSA-RP140GA
ON
PSH-P140GAH
OFF
PSA-RP125GA
S
Y
M
B
O
L
N
I.B
SW1
SWITCH (MODEL SELECTION) See Table 1.
SW2
SWITCH (CAPACITY CODE) See Table 2.
SWE
SWITCH (EMERGENCY OPERATION)
RELAY (LOUVER)
X2
X4
RELAY (FAN MOTOR)
X5
RELAY (FAN MOTOR)
X6
RELAY (FAN MOTOR)
R.B
WIRED REMOTE CONTROLLER BOARD
TB6
TERMINAL BLOCK (REMOTE CONTROLLER
TRANSMISSION LINE)
HEATER
FS1,2
THERMAL FUSE (110˚C16A)
H
HEATER
26H
HEATER THERMAL SWITCH
88H
HEATER CONTACTOR
YLW
CNSK
CN2S
(WHT)
(RED)
ORN
2
3
1
2
DC13.1V
1
POWER
1 3
1 2
1 3
CND
INDOOR/OUTDOOR
POWER
(ORN)
COMMUNICATION
CN2D
CN3C
(WHT)
CN51
(BLU)
ZNR
LIQUID
WIRELESS
2
CN21
CN90
1
(WHT)
(WHT)
INTAKE
2
CN20
REMOCON
2
1
(RED)
CN22
1
(BLU)
PIPE
2
CN29
1
(BLK)
CN2L
CN24
CN41
CN32
R.B
BLU
1
BLU
2
TRANSMISSION
TB6
WIRES DC12V
88H
FS2
FS1
5
3
RED
RED
RED
1
WHT
BLU
2
GRN/YLW
H
1 ; When work to supply power separately to Indoor and Outdoor unit
was applied, refer to Fig1.
2 ; For power supply system of this unit, refer to the caution label
located near this diagram.
[NOTES]
1.Symbols used in wiring diagram above are,
2.Indoor and outdoor connecting wires are made with polarities, make wiring
matching terminal numbers (S1,S2,S3).
3.Since the outdoor side electric wiring may change be sure to check the outdoor
unit electric wiring for servicing.
4.This diagram shows the wiring of Indoor and Outdoor connecting wires
(specification of 230V), adopting superimposed system of power and signal.
PSA-RP140GA
A
M
E
S
Y
M
B
O
L
C
CAPACITOR (FAN MOTOR)
MF
FAN MOTOR
LOUVER MOTOR
ML
TB2
TERMINAL BLOCK (HEATER) PSH-P.GAH
models only or option for PSA-RP.GA models.
TB4
TERMINAL BLOCK
(INDOOR/OUTDOOR CONNECTING LINE)
TH1
ROOM TEMP.THERMISTOR
(0˚C/15kΩ, 25˚C/5.4kΩ DETECT)
TH2
PIPE TEMP.THERMISTOR/LIQUID
(0˚C/15kΩ, 25˚C/5.4kΩ DETECT)
TH5
COND./EVA.TEMP.THERMISTOR
(0˚C/15kΩ, 25˚C/5.4kΩ DETECT)
TB4
S1
TO
S2
OUTDOOR
S3
UNIT
TB2
1 (Fig.1)
L
RED
BLU
N
GRY/YLW
TB4
RED
S1
BLU
S2
S3
I.B
1
3
1
3
POWER
INDOOR/OUTDOOR
CND
COMMUNICATION
(ORN)
CN3C
(BLU)
TB2
L
POWER SUPPLY
N
~(1 PHASE)
230V 50Hz
Esquemas eléctricos
N
A
M
E
Please set the voltage using the
remote controller.
For the setting method, please refer to
the indoor unit Installation Manual.
POWER SUPPLY
~(1PHASE)
230V 50Hz
TO
OUTDOOR
UNIT
: Connector,
: Terminal (block).
655