General; Cleaning - ESAB m2 plasma Smart Plasmarc 200 Manual De Instrucciones

Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

Maintenance

General

WARNING
WARNING
CAUTION

Cleaning

Regularly scheduled cleaning of the Plasma Console is required to help keep the unit running trouble free.
The frequency of cleaning depends on environment and use.
1. Turn power off at wall disconnect.
2. Remove side panels.
3. Use low pressure compressed dry air, remove dust from all air passages and components. Pay particular
attention to heat sinks in the front of the unit. Dust insulates, reducing heat dissipation. Be sure to wear
eye protection.
CAUTION
WARNING
Maintenance/troubleshooting
ELECTRIC SHOCk CAN kILL!
SHUT OFF POWER AT THE LINE (WALL) DISCONNECT BEFORE AT-
TEMPTING ANY MAINTENANCE.
EYE HAzARD WHEN USING COMPRESSED AIR TO CLEAN.
Wear approved eye protection with side shields when cleaning the Plasma
Console.
Use only low pressure air.
Maintenance On This Equipment Should Only Be Performed By
Trained Personnel.
Air restrictions may cause plasma unit heat to over heat.
Thermal Switches may be activated causing interruption of function.
Do not use air filters on this unit.
keep air passages clear of dust and other obstructions.
ELECTRIC SHOCk HAzARD!
BE SURE TO REPLACE ANY COVERS REMOVED DURING CLEANING
BEFORE TURNING POWER BACk ON.