Site Preparation
Plumbing Requirements
Installation must comply with all applicable plumbing codes.
Locate the water supply line within the shaded area shown
in the illustration below. Connect the water supply line to
the house supply with an easily accessible shut-off valve.
Do not use self-piercing valves. The water supply line must
be flush with the floor and cannot interfere with the instal-
lation of the anti-tip bracket.
Column and tall models with an ice maker or water dis-
penser feature a water filtration system. An in-line filter is
required for drawer models with an ice maker when water
conditions have a high sediment content.
A reverse osmosis system can be used provided there is
constant water pressure of 35–120 psi
plied to the unit at all times. In this application, the water
filtration system must be bypassed. Refer to Water Filter
Bypass on page 18. A copper line is not recommended for
this application.
WATER SUPPLY LOCATION
18" Model
24" Model
30" Model
36" Model
RIGHT SIDE
OF OPENING
A
6"
(152)
3"
(76)
AREA EXTENDS 1
/
"
2
(13)
FORWARD ON FLOOR
Water supply location
6 | Sub-Zero Customer Care 800.222.7820
PLUMBING REQUIREMENTS
Water Supply Line
Water Pressure
Excess Water Line for Connection
sup-
(2.4–8.3 bar)
A
3"
(76)
5 1/2"
(140)
6"
(152)
9"
(229)
1/4" OD copper, braided
stainless steel, or PEX tubing
35–120 psi
(2.4–8.3 bar)
36"