Temperature Unit Setting: Switch off the fridge, press
until E1 displays, then switch to E5 by pressing
+
-
or
to select Celsius or Fahrenheit. (*Factory setting is Celsius.)
Battery Protection Mode: Press
press0 again to select protection mode H(High), M(Middle) and L(Low)
(*Factory setting is H.) H should be set when the product is connected to car
power, and M or L should be set when it is connected to a portable battery or
other back-up battery.
Due to the different output voltages between vehicles, H should be set when
the product is connected to car power, and M or L should be set when it is
connected to a portable battery or other back-up battery.
The battery gear should be set from H to M or from M to L if there is a voltage
protection code F1 shown on the panel. The battery gear should be set to H if
the product keeps working after turning off the car engine, or the product may
drain the battery.
VOLTAGE REFERENCE
Input
Mode
L
M
H
*USB output: +5V DC/1A, suitable for small devices like mobile phones, tablets,
etc.
Reset: switch off the fridge, press
at the same time until the display looks as follows:
www.newair.com
for three seconds until screen flashes, then
DC 12V
CUT IN
CUT OUT
9.0V
10.9V
10.1V
11.4V
11.1V
12.4V
until E1 displays, under E1 mode, press
for three seconds
again. Under E5 mode, press
DC 24V
CUT IN
CUT OUT
21.3V
22.3V
24.3V
EN
22.7V
23.7V
25.7V
+
-