Installation Variants - Oase AquaMax Eco Premium 4000 Puesta En Marcha

Ocultar thumbs Ver también para AquaMax Eco Premium 4000:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 27
1
Inlet 1 (suction side)
• Filter housing
2
Inlet 2 (suction side)
• Connection of a satellite filter or skimmer.
• The flow rate at inlet 2 and with it the flow ratio of inlet 1 to inlet 2 is adjustable. To do so, re-
lease the locking mechanism and push the connection to one of the following positions:
− Position 0: Inlet 2 is closed, water flow only via inlet 1.
− Position 1/2/3: Inlet 2 is open by approx. 25/50/75 %; meaning water flow via inlet 1 and 2 ac-
cording to set intake ratio.
− Position 4: Inlet 1 is closed, water flow only via inlet 2.
3
Outlet (pressure side)
• Connection of the return line into the pond (e.g. via a water course).
4
Power cable
5
Hose sleeve for outlet (recommendation).
6
Stepped hose adapter for inlet 2 and outlet (alternative).
7
Cover cap for closing inlet 2 when it is not in use.
8
Hose clips for fastening hoses on the hose sleeves.
9
Rubber feet for pump holder for dry installation.

Installation variants

 A
• Variant (a): Water flow only via the filter housing (inlet 1).
– Set inlet 2 to position "0".
– Close inlet 2 using the cover cap.
• Variant (b): Water flow via the filter housing (inlet 1) and additionally via a satellite filter or
a skimmer on inlet 2.
– Set inlet 2 to position "1", "2" or "3", depending on the desired flow ratio (25/50/75 %).
• Variant (c): Water flow only via a satellite filter or a skimmer on inlet 2.
– Set inlet 2 to position "4".
• Variant (d): Dry pump installation.
– This variant requires the pump to be installed without a filter housing.
– The pump is installed outside of the pond but lower than the water level.
12

Publicidad

Capítulos

Tabla de contenido
loading

Tabla de contenido