Table of contents
Setup .......................................................................................... 4
Operation ................................................................................... 5
Priming the Pump ................................................................ 5
Painting ............................................................................... 5
cleanup ..................................................................................... 8
Maintenance ............................................................................ 10
Troubleshooting ..................................................................... 11
Parts List ................................................................................. 32
Warranty .................................................................................. 39
General Description
This fine finish spray system is versatile enough to use for
low pressure fine finish work as well as high pressure airless
spraying. The system includes a diaphragm paint pump and an
air compressor that work together to provide this versatility.
Material Pressure
Gauge
PRIME/SPRAY
Valve
Setup
Use this procedure to set up the spray system.
1. Make sure the pump ON/OFF switch and the compressor
ON/OFF switch are in the OFF position.
Compressor
ON/OFF
Switch
Pressure Control Knob
2. Make sure the pressure control knob is turned fully
counterclockwise to its lowest pressure setting.
English
Air Pressure
Regulator
Air Compressor
Air Outlet
Fitting
Air
Pressure
Gauge
Material
Outlet Fitting
Diaphragm Pump
Pump ON/OFF
Switch
3. Lock the gun by flipping the trigger lock into lock position
(see spray gun manual).
4. Using a wrench, attach a minimum of 50' of 1/4" nylon
airless spray hose to the material outlet fitting on the
pump. Tighten securely.
5. Attach the spray hose to the material inlet fitting on the
spray gun. Using two wrenches (one on the gun and one
on the hose), tighten securely.
Standard Hose
Configuration:
Air Inlet
Fitting
Coupling
Air Hose
With Optional
Whip Hoses:
Air Whip
Air Hose
Material Hose
Make sure all airless hoses and spray guns are
electrically grounded and rated for at least 2800
PSI (19 MPa) fluid pressure.
6. Attach the air hose to the air outlet fitting on the
compressor. Tighten securely.
7. Attach the air hose coupling to the air inlet fitting on the
spray gun. Attach the air hose to the coupling. Tighten
securely.
Reversing the hose connections could result in
serious injury. Make sure the airless spray hose is
connected from the diaphragm pump to the
material inlet fitting on the gun and the air hose is
connected from the compressor to the air inlet
fitting on the gun.
8. Make sure the electrical service is 120V, 15 amp
minimum.
9. Plug the power cord into a properly grounded outlet at
least 25' from the spray area.
IMPORTaNT: always use a minimum 12 gauge, three-wire
extension cord with a grounded plug. Never remove the
third prong or use an adapter.
4
Material
Inlet
Fitting
Material
Hose
Air Inlet
Fitting
Material
Inlet
Coupling
Fitting
Material
Hose
Whip Hose
Straps