Equivalent Additional Pressure Loss; Electrical Connections; Accessing The Boiler Electrical Connection Board - De Dietrich INIDENS 24 Manual De Instalación Y Mantenimiento

Ocultar thumbs Ver también para INIDENS 24:
Tabla de contenido

Publicidad

Idiomas disponibles
  • ES

Idiomas disponibles

  • ESPAÑOL, página 210
en
6 Installation
Flue gas pipes
[mm]
Ø 50 mm
rigid and flexible
Ø 60 mm
rigid
6.5.11

Equivalent additional pressure loss

Tab.112 Additional pressure loss equivalent to linear pipe length (L)
Elbow angle
90
45
Important
Information on flue gas exhaust pipes sold by the manufacturer.
6.6

Electrical connections

The electrical safety of the equipment is only ensured when it is correctly connected to an effective earthing system in
accordance with the prevailing safety standards for installations (Italian Ministerial Decree no. 37 dated 22.01.08).
The boiler must be electrically connected to a 230 V single-phase + earth mains supply.
Caution
This connection must be made using a two-pole switch with contact opening of at least 3 mm.
The power supply cable must be a harmonised "HAR H05 VV-F" 3x0.75 mm
Warning
Check that the total nominal consumption of the accessories connected to the appliance is less than 1 A. If it is
higher, a relay must be installed between the accessories and the power circuit board.
6.6.1

Accessing the boiler electrical connection board

To access the boiler components you must unscrew the two screws (1) below the panel, then remove the front panel (2). To
access the electrical connection board, turn the control panel downwards (3) then open the cover (4) by releasing the four
catches (do not use excessive force as this could break the plastic hooks).
178
INIDENS
L2 [m]
1-5
6-10
11-15
16-20
21-25
26-30
1-10
11-20
21-30
Elbow Ø 60/100 mm
Elbow Ø 80 mm
[m]
[m]
1
0.5
0.5
0.25
2900
2900
3000
3050
3150
3200
2900
3050
3200
* Setting for adjusting the fan rpm
Important
Information on flue gas exhaust pipes sold by the manufacturer.
Elbow for exhausts
Ø 60 mm rigid and
Ø 50 mm flexible
[m]
2
-
2
cable with a maximum diameter of 8 mm.
30/35 MI
8650
9500
8850
9700
9400
10000
9600
10300 (P=32 kW)
10000
10300 (P=30 kW)
10200
10300 (P=28 kW)
8650
9500
9400
10000
10100
10300 (P=28 kW)
Elbow for exhausts Ø
50 mm rigid
[m]
3
-
7804841 - 02 - 20012022

Publicidad

Tabla de contenido
loading

Este manual también es adecuado para:

Inidens 20/24 miInidens 24/28 miInidens 30/35 mi

Tabla de contenido