en
6 Installation
Flue gas pipes
[mm]
Ø 50 mm
rigid and flexible
Ø 60 mm
rigid
6.5.11
Equivalent additional pressure loss
Tab.112 Additional pressure loss equivalent to linear pipe length (L)
Elbow angle
–
90
45
Important
Information on flue gas exhaust pipes sold by the manufacturer.
6.6
Electrical connections
The electrical safety of the equipment is only ensured when it is correctly connected to an effective earthing system in
accordance with the prevailing safety standards for installations (Italian Ministerial Decree no. 37 dated 22.01.08).
The boiler must be electrically connected to a 230 V single-phase + earth mains supply.
Caution
This connection must be made using a two-pole switch with contact opening of at least 3 mm.
The power supply cable must be a harmonised "HAR H05 VV-F" 3x0.75 mm
Warning
Check that the total nominal consumption of the accessories connected to the appliance is less than 1 A. If it is
higher, a relay must be installed between the accessories and the power circuit board.
6.6.1
Accessing the boiler electrical connection board
To access the boiler components you must unscrew the two screws (1) below the panel, then remove the front panel (2). To
access the electrical connection board, turn the control panel downwards (3) then open the cover (4) by releasing the four
catches (do not use excessive force as this could break the plastic hooks).
178
INIDENS
L2 [m]
1-5
6-10
11-15
16-20
21-25
26-30
1-10
11-20
21-30
Elbow Ø 60/100 mm
Elbow Ø 80 mm
[m]
[m]
1
0.5
0.5
0.25
2900
2900
3000
3050
3150
3200
2900
3050
3200
* Setting for adjusting the fan rpm
Important
Information on flue gas exhaust pipes sold by the manufacturer.
Elbow for exhausts
Ø 60 mm rigid and
Ø 50 mm flexible
[m]
2
-
2
cable with a maximum diameter of 8 mm.
30/35 MI
8650
9500
8850
9700
9400
10000
9600
10300 (P=32 kW)
10000
10300 (P=30 kW)
10200
10300 (P=28 kW)
8650
9500
9400
10000
10100
10300 (P=28 kW)
Elbow for exhausts Ø
50 mm rigid
[m]
3
-
7804841 - 02 - 20012022