Dyna-Glo SIGNATURE Serie Manual De Instrucciones página 33

Ocultar thumbs Ver también para SIGNATURE Serie:
Tabla de contenido

Publicidad

Idiomas disponibles

Idiomas disponibles

TROUBLESHOOTING
PROBLEM
POSSIBLE CAUSE
Control Panel
• LEr - Low Temperature Alarm
Error Code
(LEr, HEr, Er1,
Er2)
• HEr - High Temperature Alarm
• Er 1 - Temperature Probe Not
• Er 2 - Temperature dial
Grill temperature fell below
120° for more than 20 minutes.
Grill temperature reaches more
than 550°. The Smoker Has
Overheated, Possibly Due
To Grease Fire Or Excessive
Pellets Inside Fire pot.
Properly Connected
security alarm.
CORRECTIVE ACTION
• LEr - This error will not affect the unit. Fire
pot fire is at risk of going out. Check the
hopper for any obstructions. Check the
fire pot for ash build up and follow the
Care and Maintenance instructions for
safely removing ash. Check the internal
temperature gauge/probe and follow the
Care and Maintenance instructions for
cleaning. Ensure that air is flowing through
the fire pot and follow the Cooking System
Check if air flow is weak. Confirm that the
auger is rotating and there is no blockage in
the auger tube. Avoid opening the lid on a
frequent basis.
• HEr - This error will not affect the unit. Turn
the temperature control dial to "Shut Down
Cycle" and allow the fan to blow until the
cycle is complete. If a grease fire occurs,
close the lid and allow the fire burn out.
Allow the unit to completely cool before
turning back on.
• Er1 - Ensure temperature probe is properly
connected to the controller board.
• Er2 - Turn the temperature control dial to
"Shut Down Cycle" and allow the fan to blow
until the cycle is complete. Once the shut-
down cycle is complete turn the unit on and
set to the desired temperature . If problem
persists, contact Customer Service for
additional support.
33

Publicidad

Tabla de contenido

Solución de problemas

loading

Tabla de contenido