2.2. INRUSH CURRENT
Maximum inrush current from power-on (with power on at any point on the AC sine) and including, but not limited to,
three line cycles, shall be limited to a level below the surge rating of the input line cord, AC switch if present, bridge
rectifier, fuse, and EMI filter components. Repetitive ON/OFF cycling of the AC input voltage should not damage the
power supply or cause the input fuse to blow.
2.3. INPUT LINE CURRENT & POWER FACTOR (P.F.)
SX300-B
(At Full load)
AC input
115V
230V
SX450-B
AC input
115V
230V
2.4. AC-DC power supplies shall not perform at less than:
(AC input=230V)
1. Power factor 0.8 at 20% of rated output.
2. Power factor 0.9 at 50% of rated output.
3. Power factor 0.95 at 100% of rated output.
3. EFFICIENCY
Under the load conditions defined in table 1. And table 2.
The loading condition for testing efficiency shown in Table 1 represents a fully loaded system. A ~ 50% (typical)
loaded system and a ~ 20% (light) loaded system.
Table1. Loading Table for Efficiency Measurements
Load
Light
Typical
Full
All manuals and user guides at all-guides.com
Input line current
< 4.5Amps – rms
< 2Amps – rms
Input line current
< 5.5Amps – rms
<3.0Amps – rms
300W(loading shown in Amps)
+3.3V
+5V
1.99
1.99
4.97
4.97
9.95
9.95
P.F.@ Full Load
P.F.@ Full Load
+12V
-12V
3.44
0.04
8.6
0.1
17.2
0.21
> 0.95
> 0.95
> 0.95
> 0.95
+5Vsb
0.34
0.86
1.72
2