3.

INSTALLATION

THE BURNER MUST BE INSTALLED IN CONFORMITY WITH LEGISLATION AND LOCAL STANDARDS.
3.1

BOILER PLATE,

Make holes in the plate shutting off the combustion chamber as il-
lustrated in fig. 2. The position of the threaded holes may be
marked using the insulating gasket supplied with the burner.
3.2

BOILER FIXING,

Carry out the following for installation:
Fasten the burner (1) to the
boiler's door (2) by means of the
four screws and (if necessary) the
nuts supplied, placing the insulat-
ing gasket (3) between the two.

3.3 PROBE AND ELECTRODE POSITIONING,

IMPORTANT
Do not turn the electrode (1): position it as illus-
trated in the figure.
Placing the electrode (1) near the ionization probe
(2) may result in the control box amplifier being
damaged.
3350
(see fig. 2)
(see fig. 3)
2
Fig. 2
3
1
(see fig. 4)
D7158
6
GB
118
140
160
D7582
Fig. 3
Fig. 4
4 mm
D7373
1
2