4) Check every 100 cycles that the machine limit switches are functioning properly.
The machine should stop automatically when the cable reaches the upper or lower
limit.
5) Check power and control cables every 100 cycles.
6) Every 200 cycles, lubricate the cable and the sheave.
7) Every 1000 cycles check:
• That all visible bolts are properly tightened.
• That the hook and block are in good condition.
• Check the operation of the brake system. The brake should be inspected if the
motor makes unusual noises during operation or the machine does not maintain
rated load.