7101-M001-0_B
GB
Page 43 of 111
AIKIDO.34LIGHT-AIKIDO.34LIGHTFI
14.0 FAULT - FINDING
Problem
The arm advance cam (in automatic
position) is immediately activated.
The nozzle doesn't supply air when
the inflation pedal is pressed (Only
for FI version).
The chuck doesn't rotate.
The chuck doesn't reach maximum
speed.
15.0 TECHNICAL DATA
Recommended air supply pressure ............. 8 - 10 bar
Motor speed .................................................. 15 rpm
Raccomanded
electric supply ......................... monophase 0,75 kW -
Maximum wheel diameter ...................... 50"/52"/54"
Wheel max. width ................................................ 15"
Rim locking diameter ........... 10"-30"÷12"-32"÷14"-34"
Bead-breaker power per roller (10bar) ........... 1200 kg
Vertical bead breaker max. opening ............... 900 mm
Gear noise ..................................................... dBA 76
15.1 Weight
Model without tubeless inflation ..................... 330 kg
Model with tubeless inflation .......................... 336 kg
All manuals and user guides at all-guides.com
INSTRUCTION, USE AND
MAINTENANCE MANUAL
Possible cause
1. The feeler pin is unscrewed.
2. The connectors are extracted.
3. The positionof the feeler pin is
out of calibration.
The inflation pedals are badly ad-
justed.
1. The first limit current is over.
2. The second limit current is over.
3. Supply missed.
4. Mains voltage insufficient.
5. Mains voltage too high.
6. Loss and prompt mains voltage.
7. The second temperature limit is
over.
1. The first temperature limit is
over.
2. Mechanical resistence is in-
creased.
200÷265V - 50/60 Hz
Rimedy
1. Screws the feeler pin properly
2. Check the connectors in the
rear part of the arm
3. Adjust the position of the feeler
pin.
Call for technical assistance.
1. Wait the automatic restoration
lifting the pedal.
2. Disconnect the machine from net
for 30 seconds at least and then
connect it again.
3. Connect the supply.
4. Shorten the lenght of the machine
extension cable or increase the
conductors section (disconnect
and hang up).
5. Disconnect the machine from net
for 30 seconds at least and then
connect it again.
6. Disconnect the machine from net
for 30 seconds at least and then
connect it again.
7. The machine DOESN'T restart
even the temperature is not un-
der the safety limit.
1. Wait for motor/inverter unit cool-
ing.
2. Turn (without wheel) the chuck
unit for few minutes. If at the end
the chuck doesn't accelerate call
for technical assistance.