PREPARATION
Before beginning installation of the product, make sure all parts are present. Compare parts with
package contents list and diagrams above. If any part is missing or damaged, do not attempt to
assemble, install, or operate the product. Contact customer service for replacement parts.
Estimated Assembly Time: 15 minutes
Tools Required for Assembly: Phillips head screwdriver (not included)
MOUNTING THE EXTENSION CORNER
1. Fasten the Metal Brackets to the appropriate holes using the provided screws (DD) and a Philips head
screwdriver as shown in Figure (3.1).
2. Fasten the Corner Extension to the installed brackets using the provided screws (DD) and a Philips
head screwdriver as shown in Figure (3.2).
STOVE LOCATION
When choosing a location for your new stove, follow the instructions listed in the <IMPORTANT
INSTRUCTIONS> section in page 2.
Cold climate installation recommendation: When installing this unit against a
non-insulated exterior wall or chase, it is mandatory that the outer walls be insulated to
conform to applicable insulation codes.

ELECTRICAL CONNECTION

A 15-Amp, 120-V, 60 Hz circuit with a properly grounded outlet is required. Preferably, the fireplace will
be on a dedicated circuit as other appliances on the same circuit may cause the circuit breaker to trip or
the fuse to blow when the heater is in operation. The unit comes standard with 6-ft. (1.83 m) three-wire
cord, exiting from the rear of the fireplace. Avoid using an extension cord. If an extension cord must be
used, it must be a minimum 14 AWG, three wire with grounding type plug connector and rated not less
than 1875 Watts. The cord shall not be more than 20 feet (6 m) in length.